Doorstrike Mode:
When programmed for Doorstrike Mode the relay is intended for door strike, maglock or gate control.
Outbound Call Mode:
When programmed for Outbound Call Mode the relay will activate continuously for the duration
of any outbound call from the Speaker phone.
Inbound/Outbound Call Mode:
When programmed for Inbound/Outbound Call Mode the relay will activate
continuously for the duration of any inbound or outbound call to or from the Speaker phone. This mode is useful for
turning on IR flood lights, for VoIP phones with cameras, etc.
Doorbell Mode:
When programmed for Doorbell Mode the speaker phone will momentarily activate the relay for the
preprogrammed relay activation time on any outbound call from the speaker phone. This mode is useful for activating
a door chime, etc. When activating door chimes, a 0.5 - 1 second relay activation time is recommended.
Alarm Mode:
When programmed in Alarm Mode the relay will activate continuously while the Speaker phone is powered
and registered to the SIP server. In the event the unit loses power and/or SIP registration the relay will turn off, which
can be used to signal an alarm device.
Note:
Alarm mode cannot be used for external relay control (
RC-4A
)
Ring Mode:
When programmed for Ring Mode the relay will continuously activate while the ringing extension is called.
This mode is useful for activating a Viking model
SL-2
strobe light, etc.
Ring Flash Mode:
When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400ms on/off
cadence while the ringing extension is called. This mode is useful for activating a Viking
LPL-1
Remote Visual Indicator,
etc.
9. Relay Mode
The one or two digit code stored in the Relay Activation Command is the touch tone command that the person being
called must enter on their phone in order to momentarily activate the relay to control a doorstrike, mag-lock, gate
controller, or other device. The code can contain the characters 0 - 9, # or
Q
. The code cannot match a relay latching
command (
Q
1,
Q
0). The code must be entered while the remote phone is communicating with the Speaker phone. The
factory setting is
.
10. Relay (Activation) Command
The value stored in the Relay Activation Time is the amount of time the relay will be energized after a correct momentary
touch tone command is entered. This number can range from 0.5 to 99 seconds. The factory setting is 5 seconds.
11. Relay Activation Time
8. Relay Internal / External
With the relay set to “Internal” the
40TB-IP
will activate its on board relay for door strike / gate control. The Relay should
be set to “External” for higher security installations when using a Viking remote model
RC-4A
relay controller to activate
the door strike / gate controller (see page 6).
The Multicast Page Length Time Out can be programmed from 1 to 255 seconds in one second increments (factory set
to 180 seconds).The Time Out can be disabled, allowing any length of page or continuous background music. A timeout
check box can be selected for each paging group. Only one timeout time can be programmed for all multicast paging
groups.
6. Multicast Page Length Time Out
The volume of each individual multicast page can be adjusted from 0-9. Factory set to 1.
7. Multicast Paging Volume
The relay activation tone is a buzzing sound that is heard from the speaker when the door strike relay is activated.
After the called party enters the correct relay activation command, the called party will hear 2 short confirmation beeps
and the entry phone will output a buzzing sound (relay activation tone) while the door strike relay is activated. The tone
(buzz) length will match the relay activation time up to a maximum of 5 seconds. The tone (buzz) can be programmed
to three different volume settings 1 = Low, 2 = Medium, 3 = High or it can be disabled.
12. Relay Buzz Volume