Page | 22
Section 5: Installing the Switch
5.0 Selecting a Site
The switch can be mounted in a standard 19-inch equipment rack or on a
flat surface. Be sure to follow the guidelines below when choosing a
location.
The site should:
o
Be at the center of all the devices you want to link and
near a power outlet.
o
Be able to maintain its temperature within 0°C to 40°C
(32°F to 104°F) and its humidity within 10% to 90%, non-
condensing.
o
Be accessible for installing, cabling and maintaining the
devices.
o
Allow the status LEDs to be clearly visible.
Make sure the twisted-pair Ethernet cable is always routed away
from power lines, radios, transmitters or any other electrical
interference.
Make sure that Vi30126 is connected to a separate grounded
power outlet that provides 100 to 240VAC and 50 to 60 Hz.
5.1 Ethernet
Cabling
To ensure proper operation when installing the switch into a network,
make sure that the current cables are suitable for 100BASE-TX or
1000BASE-T operation. Check the following criteria against the current
installation of your network:
Cable type: Unshielded twisted pair (UTP) or shielded twisted pair
(STP) cable with RJ-45 connectors; Category 5 or Category 5e
with maximum length of 100 meters is recommend 100BASE-TX,
and Category 5e or 6 with maximum length of 100 meters is
recommend for 1000BASE-T.
Protection from radio frequency interference emissions.
Electrical surge suppression.
Separation of electrical wires and data based network wiring.
Safe connections with no damaged cables, connectors or shields.
Summary of Contents for MaxiiNet Vi30126 Series
Page 15: ...Page 15 Contact Information 126...
Page 19: ...Page 19 3 4 Vi30126 Front View 3 5 Vi30126 Rear View...
Page 34: ...Page 34 After logging in the following page will appear Full Version Lite Version...
Page 41: ...Page 41...
Page 42: ...Page 42 Section 10 PoE 10 0 PoE Status...
Page 44: ...Page 44...
Page 49: ...Page 49...
Page 55: ...Page 55 Duplex Select Full or Half Duplex for most application select Full...
Page 60: ...Page 60 11 2 Bandwidth Control...
Page 70: ...Page 70 NOTE all ports which are not excluded will be part of the VLAN...
Page 73: ...Page 73 13 1 Drop and Receive Packet 13 2 CRC error packet and Receive Packet...
Page 80: ...Page 80 Section 15 Security 15 0 MAC Address Binding...
Page 89: ...Page 89...
Page 93: ...Page 93...
Page 104: ...Page 104...