41
With on, the system is not
inflating to the set pressure.
1-Insufficient pressure in the
air tank (which must be 10 PSI
higher than the maximum set
pressure) caused by:
a) Incorrect tank selection for
air supply to the control
module.
b) Defective compressor
operation.
c) Compressor cut-off valve
with low calibration.
2-Obstructed Air Filter.
3-Strangled connecting hose
between air tank and control
module.
5-Control module damage.
1-
a) Correctly select air tank
according to installation
instructions for the air filter.
b) Repair compressor.
c) Adjust the compressor cut-
off valve. Repair if necessary.
2-Clean the air filter.
3-Replace hose.
5-Replace control module.
Pressure falls and system
does not recover – Indicator
off.
1-Calibration altered.
2-Display module damage.
1-Calibratet the VIGIA Display
Module again.
2-Replace display module.
The air continues to leak from
the tires while disconnecting a
hose from the network.
1-Leak in tire valves.
1-a) Activate the valve's
internal piston with a blunt
element.
b) Take the valve out and
blow through the intake end,
adding soapy water. Check
for closing tightness, and
replace if necessary.
With the system disconnected,
air leaks from the control
module while disconnecting a
hose from the network.
1-Control Module damage.
1-Replace control module.