38
5
- FINAL SYSTEM TESTING (in operation)
1- Verify that there are no air leaks in the system by turning off the system. If there are any leaks, the
pressure readings will drop.
To detect air leaks, use soapy water and monitor all connections and
joints.
Note:
To facilitate detection of small air leaks, isolate the system network by sections through the use of
plugs.
2 - Verify the operation of the safety mechanism by producing a very large air leak (For example, take a
plug out, press the brakes repeatedly, etc.) - The Air Tank (P) pressure will be shown and the alarm will
sound.
3- Confirm that air is reaching each tire.
4- Verify, after a few minutes, the correct pressure readings with respect to the set calibration.
5- Clean all the working surfaces.
6- Control the adjustment and aesthetics of all the elements: fastening nuts, hoses, body couplings, etc.
7- Verify that there are no air leaks in the air filter.