110
Rated heating output range (to EN 15502-1)
T
F
/T
R
= 50/30 °C (P(50/30))
Natural gas
kW
1.9 - 19
1.9 - 25
1.9 - 32
LPG
kW
2.5 - 19
2.5 - 25
2.5 - 32
T
F
/T
R
= 80/60 °C (Pn(80/60))
Natural gas
kW
1.7 - 17.4
1.7 - 22.9
1.7 - 29.3
LPG
kW
2.2 - 17.4
2.2 - 22.9
2.2 - 29.3
Permiss. operating pressure, DHW side (PWM)
bar
MPa
10
1
10
1
10
1
Specific flow rate
l/h
20.26
23.84
25.87
Max. DHW temperature
°C
60
60
60
Dimensions
Length
mm
595
595
595
Width
mm
600
600
600
Height
mm
1400
1400
1400
Gas connection
R
¾
¾
¾
Flue gas connection
Ø mm
60
60
60
Ventilation air connection
Ø mm
100
100
100
Connection values
relative to max. load
With gas
Natural gas E
m
3
/h
2.40
3.12
3.69
Natural gas LL
m
3
/h
2.79
3.63
4.29
LPG
kg/h
1.76
2.29
2.71
Flue gas values
Mass flow rate (for DHW heating)
■
Natural gas
g/s
40.4
54.2
62.1
■
LPG
g/s
39.8
53.2
61.1
Temperature (for DHW heating)
°C
67
72
77
Max. temperature
°C
120
120
120
Note
The supply values are only for reference (e.g. in the
gas contract application) or for a supplementary, rough
estimate to check the volumetric settings. Due to fac-
tory settings, the gas pressure must not be altered
from these values. Reference: 15 °C, 1013 mbar
(101.3 kPa).
Type of flue system
Available in the following countries
Type of flue system
AE, AM, AT, BA, BG, BY, CH, CY, CZ, DK, EE, ES,FI,
GB, GR, HR, HU, IE, IS, IT, KG, KZ, LI, LT, LU, LV, MT,
NL, NO, PL, PT, RO, RS, RU, SE, SK, TR, UA
B
23
, B
33
, C
13
, C
33
, C
43
, C
53
, C
63
, C
83
, C
93
BE
B
23
, B
23P
, B
33
, C
13
, C
33
, C
43
, C
53
, C
83
, C
83P
, C
93
DE, SI
B
23
, B
33
, C
13X
, C
33X
, C
43X
, C
53X
, C
63X
, C
83X
, C
93X
FR
B
23
, B
23P
, B
33
, C
13
, C
33
, C
43
, C
53
, C
63
, C
83
, C
83P
C
93
Specification
Specification
(cont.)
6130884
Service