Coding in the delivered condition
Possible change
FA:20
Raising the set boiler
water temperature or
the set flow temperature
when changing from op-
eration with reduced
room temperature to op-
eration with standard
room temperature, by
20 %. See example on
page 100 (only for
weather-compensated
control units).
FA:0
to
FA:50
Temperature rise adjusta-
ble from 0 to 50 %
Fb:30
Duration for raising the
set boiler water tem-
perature or the set flow
temperature (see cod-
ing address "FA")
60 min. See example on
page 100 (only for
weather-compensated
control units).
Fb:0
to
Fb:150
Duration adjustable from
0 to 300 min;
1 step
≙
2 min
Resetting codes to their delivered condition
Constant temperature control unit:
1.
L
+
G
simultaneously for
approx. 2 s.
2.
e
press.
Weather-compensated control unit:
1.
L
+
G
simultaneously for
approx. 2 s.
2.
e
"
Factory set? Yes
"
appears.
3.
d
to confirm
or
a
/
b
to select "
Factory set?
No
".
Code 2
(cont.)
59
Coding
5692
761
GB