76
A
Wiring chamber, heat pump stage 2
(type BWS 351.A07)
B
< 42 V LV connecting cables:
■ With plugs
aJ
B and
aVG
for the
wiring chamber for heat pump
stage 2 (type BWS 351.A07).
■ With plugs "X6" and
aVG
for the
wiring chamber for heat pump
stage 1 (type BW/WW 351.A07).
C
230 V~ connecting cables:
■ With plugs without ID for the wir-
ing chamber, heat pump stage 2
(type BWS 351.A07).
■ With plugs "X300" and
aBH
for the
wiring chamber, heat pump stage
1 (type BW/WW 351.A07).
D
Wiring chamber, heat pump stage 1
(type BW/WW 351.A07)
Overview of the electrical connections of the heat pump control
unit (type BW/WW 351.A07 and BWC/WWC 351.A07)
Note
■ Route 230 V~ cables and LV cables
separately and bundle them tightly
together at the terminals. This ensures
that, in case of failure, for example
when detaching a wire, the wires can-
not drift into the adjacent voltage area.
■ Strip the insulation as close to the ter-
minals as possible.
■ If two components are connected to
the same terminal, press both wires
together into a single wire ferrule.
Installation sequence
Electrical connections
(cont.)