13
Recommended power cables for all types:
Cable cross-section
Max. cable length
Heat pump control unit
(230 V~)
3 x 1.5 mm
2
(5 x 1.5 mm
2
with pow-
er-OFF)
–
Compressor (400 V~)
5 x 2.5 mm
2
50 m
Instantaneous heating water
heater (400 V~, if installed)
5 x 2.5 mm
2
50 m
Overview of possible system schemes
The following table provides an overview
of
all
possible system schemes.
Selected system schemes are explained
using system examples (see from
page 45).
Overview of all available system schemes
Component
"System scheme 7000"
0
1
2
3
4
5
6
7
8
9
10
11
Heating circuit
A1/HC1
–
X
X
–
–
X
X
–
–
X
X
–
M2/HC2
–
–
–
X
X
X
X
X
X
X
X
–
M3/HC3
–
–
–
–
–
–
–
X
X
X
X
–
DHW cylinder
X
–
X
–
X
–
X
–
X
—
X
–
Heating water buffer cylinder
–
0
0
X
X
X
X
X
X
X
X
–
External heat source
0
0
*1
0
*1
0
0
0
0
0
0
0
0
–
Instantaneous heating water heater
0
0
0
0
0
0
0
0
0
0
0
–
Swimming pool
–
0
0
0
0
0
0
0
0
0
0
–
Solar thermal system
(in conjunction with Vitosolic 200)
0
–
0
–
0
–
0
–
0
–
0
–
*1
Only in conjunction with a heating water buffer cylinder.
Preparing for installation
Siting
(cont.)
5609 667 GB
Installation