57
Parameter
Setting
"Cooling"
■
"Cooling 7100"
"3"
■
"Cooling circuit 7101"
"4"
DHW heating:
"Time program DHW"
Set time program (see op-
erating instructions)
"Time prog DHW circ"
Set time program (see op-
erating instructions)
"DHW"
■
"Enable booster heaters for DHW heating 6014" "1"
"Electr booster heater"
"Enable instantaneous heating water heater 7900" "1"
"Enable instant. heating water heater for central
heating 7902"
if required
"1"
"Output for instant. heating water heater at power-
OFF 790A"
■
"1"
for 3 kW
■
"2"
for 6 kW
■
"3"
for 9 kW
"Heating water buffer cylinder"
■
"Enable buffer cylinder/low loss header 7200"
"1"
Remote control units
:
"Heating circuit 1"
■
"Remote control 2003"
"1"
"Heating circuit 2"
■
"Remote control 3003"
"1"
System example 3, ID: 4605352_1008_01
Note
Type BW/WW 351.A07 is illustrated. In
type BWC/WWC 351.A07, the circula-
tion pumps (primary pump, secondary
pump and circulation pump for cylinder
heating) are fitted and connected at the
factory.
Selecting system scheme 10
■ Single stage heat pump, type BW
351.A07
■ 1 heating circuit without mixer A1/HC1
■ 2 heating circuits with mixer M2/HC2,
M3/HC3
■ External heat source for central heat-
ing and DHW
■ DHW heating with solar backup
■ Solar thermal system
■ Heating water buffer cylinder
■ Natural cooling function via heating
circuit M2/HC2
■ Swimming pool
Preparing for installation
System example 2, ID: 4605351_1008_01
(cont.)
5609 667 GB
Installation