12
is first disconnected for about 20 ms whenever the
point motor is activated. First the point motor is
active and only then the power to the frog will be
reconnected with the correct polarity.
All digital commands to the output controlling the
polarity will be ignored as long as the polarizing
option is active.
CV 43/CV 44:
Value 0: Polarity control inactive.
Value 1: Polarity control active, regardless of the
feedback from the point motor.
Value 2: Polarity control active, taking into account
the feedback from the point motor. Polarity control
is only active if the physical status of the point de-
termined by the feedback conforms with the most
recent command to the point motor.
Herzstück
Frog
+
10uF/35V 10uF/35V
+
Digital-
zentrale
Digital
command
station
1,2 kOhm/0,25 W
1,2 kOhm/0,25 W
Abb. 7
Fig. 7
schaltet erst die Polarisierung für ca. 20 ms aus,
um einen Kurzschluss an den Weichen-
zungen zu vermeiden. Anschließend schaltet die
Weiche, danach die Polarisierung mit der geän-
derten Polarität wieder ein.
Während die Polarisierungsoption aktiv ist, wer-
den konsequenterweise Digitalbefehle an dem
Ausgang, der die Polarisierung antreibt, ignoriert.
CV 43/CV 44:
Wert 0: Weichenpolarisierung inaktiv.
Wert 1: Polarisierung aktiv, ohne Berücksichtigung
der Weichenrückmeldung.
Wert 2: Polarisierung aktiv, mit Berücksichtigung
der Weichenrückmeldung. Die Polarisierung
schaltet nur dann ein, wenn die physikalische
Position der Weiche, gemessen durch die Rück-
meldung, mit dem Weichenbefehl übereinstimmt.
Summary of Contents for 5280
Page 27: ...27 Notizen Notes ...
Page 28: ...28 Notizen Notes ...