Installation Instructions
21 of 38
IM-PP 724607 1218 ProPress
Tube Diameter
(inches)
A minimum
(inches)
A minimum
(mm)
B minimum
(inches)
B minimum
(mm)
½
¾
19
1⅝
41
¾
⅞
22
2⅛
54
1
1
26
2½
64
1¼
1⅛
29
2⅞
73
1½
1¾
45
3½
89
2
2
51
4⅜
111
Table 4: ProPress standard jaws clearance requirements
Tube
Diameter
(inches)
A
minimum
(inches)
A
minimum
(mm)
B
minimum
(inches)
B
minimum
(mm)
C
minimum
(inches)
C
minimum
(mm)
½
⅞
23
1 ⅜
35
2 ½
64
¾
1
26
1 ½
38
2 ½
64
1
1 ⅛
29
1 ¾
45
3
76
1 ¼
1 ¼
32
2 ¼
57
3 ⅛
80
1 ½
1 ⅞
48
2 ½
64
3 ¾
95
2
2 ⅛
54
3 ⅛
80
5
127
Table 5: ProPress standard jaws clearance requirements between tube, wall, and floor
Tube Diameter
(inches)
A minimum
(inches)
A minimum
(mm)
B minimum
(inches)
B minimum
(mm)
½
¾
19
2
51
¾
⅞
22
2⅜
60
1
26
2⅝
67
1¼
1⅛
28
3⅛
85
Table 6: ProPress compact jaws clearance requirements
Tube
Diameter
(inches)
A
minimum
(inches)
A
minimum
(mm)
B
minimum
(inches)
B
minimum
(mm)
C
minimum
(inches)
C
minimum
(mm)
½
⅞
23
1⅜
35
2½
64
¾
1
26
1½
38
2¾
70
1
1⅛
29
1⅝
41
3
76
1¼
1⅝
39
2⅛
53
3⅜
85
Table 7: ProPress compact jaws clearance requirements between tube, wall, and floor
A
B
A
B
C
20°
A
B
A
B
C
20°