Screw plastic union nut back onto wall lead-in.
Re-mount (SW 19) the flexible hose onto the corner valve.
3.2.3
Preparing optional actuation versions
The corresponding empty pipe (included in the scope of delivery of the
remote actuation) is required when preparing the remote actuation
Visign for Public1 (model 8326.21).
Lead the empty pipe from the hollow wall socket into the concealed
cistern.
Distance from the remote actuation to the cistern (x)
n
min. 1.0 m
n
max. 1.7 m
A corresponding empty pipe (not included in the scope of delivery of the
electrical actuation) is required for the preparation of the electrical
actuation (model 8350.31 or model 8350.32).
Prepare remote actuation
X
X
Prepare electrical actuation
Handling
Viega Eco Plus WC element, height-adjustable after installation
29 from 33