Attach WC element to the support profiles using the screws sup-
plied.
Connect the WC element flush with the support profiles.
Screw in the threaded rods for WC ceramic at 350 mm aligned with
the finished floor.
INFO! Do not counter the threaded rods. All that needs to be
done during subsequent height adjustment is to loosen the
fixing nuts of the WC ceramic.
Clip in drain elbow.
Vertical connection: Do not lay the drain elbow in a concrete floor so
that the flexibility of the connection pipe is retained.
4x
19
click
Handling
Viega Eco Plus WC element, height-adjustable after installation
21 from 33