3 Handling
3.1
Assembly information
3.1.1
Mounting conditions
The WC element can be mounted on the following walls:
n
masonry walls in acc. with DIN EN 1996-1-1
n
concreted walls in acc. with DIN 1045
n
metal support profile in acc. with DIN 18183
The WC element may only be mounted on even wall surfaces.
With the construction height, the marked height of the upper edge of
the finished floor must be observed.
The installation depth can be between 130 mm and 200 mm.
The WC element can only be used in combination with wall-hung WCs
(fixing gauges for bore hole 180 mm or 230 mm).
The WC element can be extended by a remote actuator
Visign for Public1 (model 8326.21) or by an electronic actuator (model
8350.31 or 8350.32). The corresponding actuation method must be pre-
pared before the WC element is clad and tiled.
The corresponding empty pipe (included in the scope of delivery of the
remote actuator) is required when preparing the remote actuation
Visign for Public1.
Suitable walls
Construction height
Installation depth
WC ceramic
Actuation
Handling