Scope / Notice
Regulations applicable in Ger‐
many
External corrosion protection
DIN EN 806-2
External corrosion protection
DIN 1988-200
External corrosion protection
DKI-Informationsdruck i. 160
Scope / Notice
Regulations applicable in Ger‐
many
Leakage test for potable water
installations
DIN EN 806, part 4
Leakage test for potable water
installations
ZVSHK-Merkblatt
„
Dichtheitsprüfungen von Trink‐
wasserinstallationen mit Druckluft,
Inertgas oder Wasser
‟
Scope / Notice
Regulations applicable in Ger‐
many
Operation and maintenance of
potable water installations
DIN EN 806-5
2.2
Intended use
Coordinate the use of the model for areas of use and media
other than those described with the Viega Service Center.
A ball valve is a fitting that is able to shut-off and open individual pipe‐
line sections through a 90° movement. The ball valve is not a control fit‐
ting and cannot be used for regulating volume flows. The ball must not
be in an intermediate position.
NOTICE!
Opening and closing the ball valve quickly can cause pres‐
sure shocks in the system.
– Always open and close the ball valve slowly.
Regulations from section: Corrosion
Regulations from section: Leakage test
Regulations from section: Maintenance
Product information
Easytop ball valve
8 from 15