n

T-shaped actuating lever made of plastic

n

protective caps for the actuating lever in the red and green for the

identification of the corresponding area of use

n

position indication open/closed

n

key surface on the casing

n

maintenance-free selector shaft

n

ball seal made of Teflon®

n

stainless steel ball

DN

15

20

25

32

40

50

Rp

½

¾

1

2

2.3.2

Threaded connection

Prerequisite for a threaded connection, which seals via a thread, is a

threaded pair in accordance with applicable regulations, see 

Ä

 „Regula‐

tions from section: Threaded connection“ on page 7

. Pursuant to these

regulations, a permitted threaded pair comprises a conical external

thread and a cylindrical internal thread, e.g. R 

¾

 and Rp 

¾

.

Only use commercially available and chloride-free, DVGW approved

sealant in accordance with the applicable regulations to seal threads,

see 

Ä

 „Regulations from section: Threaded connection“ on page 7

.

2.3.3

Markings on components

The model is marked as follows:

n

noise class I pursuant to applicable regulations, see 

Ä

 „Regulations

from section: Marking on components“ on page 7

n

Dimension

n

DVGW writing

n

Position indicator on the actuating lever

2.3.4

Compatible components

Please contact the Viega Service Center for questions on this subject.

2.3.5

Technical data

Observe the following operating conditions for the installation of the

model:

Product information

Easytop ball valve

10 from  15

Summary of Contents for 2270.2

Page 1: ...Model Year built 2275 2 from 07 2017 en_INT Easytop ball valve Instructions for Use...

Page 2: ...Easytop ball valve 2 from 15...

Page 3: ...2 Media 9 2 3 Product description 9 2 3 1 Overview 9 2 3 2 Threaded connection 10 2 3 3 Markings on components 10 2 3 4 Compatible components 10 2 3 5 Technical data 10 2 4 Information for use 11 2 4...

Page 4: ...operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and adv...

Page 5: ...or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The rele...

Page 6: ...ng execution operation and maintenance of potable water installations DIN EN 806 part 5 Planning execution operation and maintenance of potable water installations DIN EN 1717 Planning execution opera...

Page 7: ...group I DIN EN 13828 Scope Notice Regulations applicable in Ger many Threaded pair DIN EN 10226 1 Permitted sealants DIN 30660 Permitted sealants DIN EN 751 2 Scope Notice Regulations applicable in Ge...

Page 8: ...e of potable water installations DIN EN 806 5 2 2 Intended use Coordinate the use of the model for areas of use and media other than those described with the Viega Service Center A ball valve is a fit...

Page 9: ...s see Regulations from section Media on page 6 n Heating water for pump hot water heating systems see Regula tions from section Media on page 6 n Compressed air in compliance with the specification of...

Page 10: ...mitted threaded pair comprises a conical external thread and a cylindrical internal thread e g R and Rp Only use commercially available and chloride free DVGW approved sealant in accordance with the a...

Page 11: ...sion protection is required observe the pertinent guide lines see Regulations from section Corrosion on page 8 Easytop fittings made of gunmetal silicon bronze are suit able for all types of potable w...

Page 12: ...Fig 1 Model 2275 93 Easytop L shaped actuating lever Fig 2 Model 2275 92 Easytop T shaped actuating lever Fig 3 Model 2275 94 Easytop thermometer Product information Easytop ball valve 12 from 15...

Page 13: ...sulating shells are available for all sizes of ball valves The two piece shells are self supporting and are mounted without tools and holding grips They connect seamlessly to the front surfaces of the...

Page 14: ...ing when mounting n Use suitable tools n Installation is not dependent on the direction of flow Choose the place of installation so that the fitting is easily accessible simple to operate and the insu...

Page 15: ...ment the result 3 3 Maintenance NOTICE Inform your customer or the operator of the potable water installation that the system has to be maintained on a reg ular basis Observe the applicable regulation...

Reviews: