V-Tap ISDN BRI Manual EN v2.6 Dec 2018 © 2017-2018 Vidicode 8
2.3
Checklist for Tunnel connection
A connection between V-Tap and Apresa or PC software is needed to
get the recorded data automatically into a user accessible database.
The following checklist can be used to setup this Tunnel connection:
1)
Install the
Hardware
.
2)
Install the Apresa or PC
Software
and enable V-Tap connections.
3)
Assign an
IP address
to the V-Tap and open the
Settings page
.
4)
The “
Tunnel Server Address
”
must be filled in with the IP
address or name of the Apresa recorder or the PC.
5)
Any
firewall
must be setup to let pass TCP port 2016, the default
“
Tunnel Destination Port
”.
6)
The Tunnel connection to the Apresa or PC software is stable
when the
GREEN LED is steady
, not blinking!
7)
For first tests, better t
urn off “
Tunnel Data Encryption
”
.
Otherwise, be sure that the Encryption password is the same for
both V-Tap and Tunnel server.
8)
When data is stored during a call then the
BLUE LED
blinks.
9)
To see if the Apresa or PC receives something from the V-Tap, it
is possible to make a network trace for test purposes.
On the PC go to menu Action and select
‘
Network trace
’
. The
'tunneltrace.pcap' file can be read afterwards with Wireshark.
10)
The SD card in the V-
Tap should contain “.
WAV
” files.
The SD card can be read by the PC software in menu File and
‘
Import from V-Tap
’
.