V-Tap ISDN BRI Manual EN v2.6 Dec 2018 © 2017-2018 Vidicode 33
5.5
Factory settings
To reset all settings to factory default, the following must be done:
•
Remove the SD card.
•
Power off the unit.
•
Press the button.
•
Power on and hold the button pressed; all LED's are ON.
•
Release the button within 5 seconds; RGB LED's go OFF.
•
Press the button 5 times again; RGB LED's blink fast.
•
After 5 seconds, the system reboots automatically.
The procedure above is only possible when the system is running
normal. With corrupted firmware, a special update must be done with
an SD card (see
Firmware update
).
5.6
Default IP address
When the application does not seem to run at all anymore, then a reset
to factory settings is not possible. Besides a special update with the SD
card (see below), there is still a way to look with FTP in the filing system
remotely. The following can be done:
•
Remove the SD card.
•
Power Off the unit.
•
Press the button.
•
Power On and hold the button pressed for 1 second.
•
Release the button.
•
The IP address is now on default 192.168.55.66
•
Only access with FTP is now possible (no web interface).