66250203-EN - V0.3 - 10/07/15

14

4000 Series Vandal Resistant Range

Art. 4212V-4212RV - Installation instructions

MODE

Options are 

COMPATIBILY MODE

 or 

NORMAL MODE

COMPATIBILITY MODE

 guarantees retrocompatibility with older program-

ming  interfaces but restricts the features of the panel.

NORMAL MODE

 enables features of floor field in user item, multiple code-to-user or key-to-user linking. This means that user can 

manage more than one open door code and key.

In 

COMPATIBILITY MODE

 each user only has one access code.

ENABLE DIRECT CALL

It specifies whether Direct Call Mode is active or not. If yes, only the  first 18 or 15 (depending on keyboard configuration) users 

written in memory are active. Pushing the first key from top left corner of keyboard will call first user memory location.

PROXIMITY ACCESS MODE

This parameter specifies if the proximity reader works in a self contained standalone mode or is connected via a Wiegand interface 

to an external controller such as Portal Plus. 

STANDALONE MODE:

 when a fob/code is used the panels internal memory is checked for a match. If a match is found the relay will 

energise and the display will show the door opening. If no match is found the display will show ‘NOT FOUND’. 

WIEGAND MODE

: When a fob/code is used the panel sends the data to the Wiegand output and awaits a reply. If the external Wie-

gand controller replies by setting the LR terminal to 0V then the fob/code is denied and the display will show ‘NOT FOUND’. If the 

external Wiegand controller replies by setting the LG terminal to 0V then the key is accepted and the display will show door open. 

If the Wiegand control does not reply then the panel will show ‘NOT FOUND’.

Art. 4212V - 4212RV 

 Audio/video digital front panel 

Programming

Summary of Contents for 4212RV

Page 1: ...alanced V1 V2 Coax V2 V V1 not used Balance V PB CHIP Made in Italy 12T GNDV V2 V V1 PTE TRD NO C NC SL BS L 12 GND OC OUTPUT D0 D1 LR LG WIEGAND A B GND RS485 Dry contact output Capacitor discharge R...

Page 2: ...era provides the best quality of view in any light condition and the wide angle camera provides a viewing angle of 170 degrees The camera can be set to work with composite video signal coax cable or b...

Page 3: ...n door if enabled see Trade on pag 12 a valid Access code the door will be open or NOT FOUND message will appear To delete digits or exit page press HOW TO CALL AN APARTMENT From stand by mode enter a...

Page 4: ...nctions to scroll back to scroll forward to alternate between capital and lower case letters For instance to type the name VIDEX it is necessary to press 3 times 8 button V 3 times 4 button I 1 times...

Page 5: ...n COMPATIBILITY MODE please refer to User parameters Code on pag 7 From Programming menu press 1 to enter the user menu then 1 to modify a user find the user by name or flat press 3 and enter in User...

Page 6: ...usly select search by key option he has to pass card fob over the symbol if searched key is present the user tag modify page will appear pressing 1 to enable disable the key press to save or to exit w...

Page 7: ...ve or to delete characters or exit edit mode without save FLAT The flat number is entered by the visitor to call a flat It can be 1 to 6 digits long Modify routine select user searching by name or fla...

Page 8: ...edit mode without save PHONE ID The phone ID represents the address of the intercom to call Set by the 8 way dip switches in the intercom Modify routine select user searching by name or flat press 6 t...

Page 9: ...en in standby Enter the string and press The have a blank line enter one or more space characters Modify routine press 1 2 or 3 to enter into edit mode enter the string press to save or to delete char...

Page 10: ...o switch from 1 12 to 0 23 and viceversa press to save or to exit edit mode without saving CLOCK Set the time on the door panel Modify routine press 1 to enter the clock menu press 2 to enter edit mod...

Page 11: ...ess 3 to enter the trade menu press 1 to enter edit mode press 1 to enable or disable the facility press to save or to exit edit mode without saving TRADE START TRADE END The beginning and end times o...

Page 12: ...nd and only when TRD is shorted to 0V It must be between 3 to 6 digits and different to all other codes Entering the correct code when the above requirements are met will open the door for the program...

Page 13: ...ave or to delete characters or exit edit mode without saving MASTER Specifies if the panel is a master or a slave On each bus there should only be one master all other panels on that bus should be sla...

Page 14: ...memory location PROXIMITY ACCESS MODE This parameter specifies if the proximity reader works in a self contained standalone mode or is connected via a Wiegand interface to an external controller such...

Page 15: ...called is pronounced singularly i e 123 one two three In COMBINED mode number called is pronounced all in one i e 123 one hundred and twenty three Modify routine press 2 to enter into edit mode press...

Page 16: ...CTION TERMINALS JUMPERS Dry contact output Capacitor discharge SWITCHES Balanced V1 V2 Coax V2 V V1 not used RS485 BUS TERMINATION Open Close CONNECTION TERMINALS 12T 12Vdc Camera power supply unit GN...

Page 17: ...66250203 EN V0 3 10 07 15 17 4000 Series Vandal Resistant Range Art 4212V 4212RV Installation instructions Art 4212V 4212RV Audio video digital front panel...

Page 18: ...66250203 EN V0 3 10 07 15 18 4000 Series Vandal Resistant Range Art 4212V 4212RV Installation instructions Art 4212V 4212RV Audio video digital front panel...

Page 19: ...out hole in the box 2 Make all the connections on the removable terminal blocks Fig 2 then plug back into the panel Fig 3 setup the dip switches as per provided connection diagram or instruction sheet...

Page 20: ...ox fix surface box to the wall using the screws G Fig 3 4 Connect the wires using a terminal screw driver then setup the dip switches as per provided connection diagram or instruction sheet then power...

Reviews: