27
z
4/8/16-ch grounding alarm inputs. (Normal open or Normal close type)
z
Please parallel connect COM end and GND end of the alarm detector (Provide external
power to the alarm detector).
z
Please parallel connect the Ground of the DVR and the ground of the alarm detector.
z
Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
z
If you need to reset the touched-off alarm remotely, you can use DVR to supply
controllable 12 V power to the alarm detector such as the smoke detector.
z
Use the same ground with that of DVR if you use external power to the alarm device.
Figure 2-8
2.7.8
Relay
Output
Description
z
6 ways relay alarm output. Provide external power to external alarm device.
z
To avoid over loading, please read the following relay parameters sheet carefully. (See
below table)
z
The contro12v can be used to restore the smoke detector.
Please refer to Figure 2-9 for alarm input module information.
Figure 3-9
Please refer to Figure 3-10 for alarm output module information.