7.3 Installation
Before doing any technical work or
maintenance on the device, make sure
that potentially explosive atmosphere is
not present. To reduce the risk of ignition
don’t open the device when a potentially
explosive atmosphere is present.
The electrical installation in which the
unit is inserted must be equipped with a
15A maximum bipolar protection circuit
(magnetothermal), that must include a
bipolar automatic-type circuit breaker,
which must also envisage earth fault
current protection (magnetot
differential) with minimum distance of
3mm between contacts.
A power disconnect device must be
included in the electrical installation, and
it must be very quickly recognizable and
operated if needed.
Before doing any technical work on the
device make sure that the power supply is
disconnected.
Do not use worn or old power cables.
The housing can be installed with a slope
that varies between ± 90° with reference to
the horizon.
The cameras to be installed shall not
contain cells or batteries.
Refer to the following images and information to
connect the wires and cables as required.
7.3.1 How to open the housing
To install the camera open the rear flange of the
enclosure.
Remove the M6 screws on the rear flange and pull
it out from housing body using the 3 M5x60mm
hexagonal head extraction screws.
Be careful not to damage the explosion
proof joint.
Fig.
15
Screws properties:
• Diameter/Screw pitch: M6x0.8
• Material: A2 or A4 Class 70
• Screw head: ISO 4762
• Length: 18mm
• Yield stress: 450N/mm²
Disconnect wiper connectors (version with
wiper).
J3
J8
Fig.
16
Summary of Contents for MAXIMUS MHX
Page 2: ......
Page 4: ......
Page 8: ...EN English Instruction manual 6 MNVCMHX_1706_EN...
Page 48: ......
Page 52: ...IT Italiano Manuale di istruzioni 6 MNVCMHX_1706_IT...
Page 92: ......
Page 96: ...FR Fran ais Manuel d instructions 6 MNVCMHX_1706_FR...
Page 136: ......
Page 140: ...DE Deutsch Bedienungsanleitung 6 MNVCMHX_1706_DE...
Page 179: ...RU MAXIMUS MHX MAXIMUS MHXT...
Page 180: ......
Page 183: ...RU 5 MNVCMHX_1706_RU 13 2 1 39 13 2 2 39 13 2 3 39 13 2 4 40 13 2 5 40 13 3 41 13 4 41 14 42...
Page 184: ...RU 6 MNVCMHX_1706_RU...
Page 185: ...RU 7 MNVCMHX_1706_RU 1 1 1 INFO 2 3 J9 7 3 3 21 1...
Page 186: ...RU 8 MNVCMHX_1706_RU 40 C 60 C IEC EN 60079 14 4 4 2 12 24Vac 10 12Vdc 5...
Page 189: ...RU 11 MNVCMHX_1706_RU 4 4 1 MHX MHX AISI 316L 3 4 NPT IEC EN60079 14 5 4mm IP66 IP67 40 C 60 C...
Page 190: ...RU 12 MNVCMHX_1706_RU 4 2 02 01 03 04 09 10 05 06 07 08 11 2 1 2 3 4 12 5 V 6 A 7 8 W 9 W...
Page 192: ...RU 14 MNVCMHX_1706_RU 5 5 1 3 5 2 4 5 3 AISI 316L 7 5 m 14 m 5 5 4 Single Mode Multi Mode 6...
Page 193: ...RU 15 MNVCMHX_1706_RU 6 6 1 15A max 3mm...
Page 194: ...RU 16 MNVCMHX_1706_RU 6 2 6 2 1 6 2 2 6 3 6 4 4...
Page 205: ...RU 27 MNVCMHX_1706_RU 7 3 7 J10 BNC BNC J10 30 62 5 125 m 3km 9 125 m 69km ST 31...
Page 211: ...RU 33 MNVCMHX_1706_RU 7 3 15 43 7 3 12 31 8 9 12Nm max 44 7 3 16 45 J9 17 22 20 23 22 24...
Page 212: ...RU 34 MNVCMHX_1706_RU 8 8 1 8 1 1 8 1 2 8 1 3 9 9 1...
Page 215: ...RU 37 MNVCMHX_1706_RU 11 2012 19 RAEE 25cm 12...
Page 223: ...KO MAXIMUS MHX MAXIMUS MHXT...
Page 224: ......
Page 227: ...KO 5 MNVCMHX_1706_KO 13 2 4 40 13 2 5 40 13 3 41 13 4 41 14 42...
Page 228: ...KO 6 MNVCMHX_1706_KO...
Page 229: ...KO 7 MNVCMHX_1706_KO 1 1 1 INFO 2 3 J9 7 3 3 21 1...
Page 230: ...KO 8 MNVCMHX_1706_KO 40 C 60 C 40 F 140 F IEC EN 60079 14 4 4 2 12 24Vac 10 12Vdc 5 A...
Page 236: ...KO 14 MNVCMHX_1706_KO 5 5 1 3 5 2 4 5 3 AISI 316L 7 5 m 14 m 5 5 4 6...
Page 237: ...KO 15 MNVCMHX_1706_KO 6 6 1 15A 3mm...
Page 238: ...KO 16 MNVCMHX_1706_KO 6 2 6 2 1 6 2 2 O 6 3 6 4 4...
Page 249: ...KO 27 MNVCMHX_1706_KO 7 3 7 CPU J10 BNC BNC J10 30 3km 62 5 125 m 69km 9 125 m ST 31...
Page 255: ...KO 33 MNVCMHX_1706_KO 7 3 15 43 7 3 12 31 o 8 9 12Nm max 44 7 3 16 45 J9 17 22 20 23 e 22 24...
Page 256: ...KO 34 MNVCMHX_1706_KO 8 8 1 8 1 1 8 1 2 8 1 3 9 9 1...
Page 259: ...KO 37 MNVCMHX_1706_KO 11 WEEE 2012 19 EU 25cm 12 Troubleshooting...
Page 267: ......