250/70
250/85
250/100
Dimensions (h x w x d)
Tr models: 185 x 250 x
95mm
MC4 models: 215 x 250 x
95mm
Tr models: 216 x 295 x 103mm
MC4 models: 246 x 295 x 103mm
STANDARDS
Safety
EN/IEC 62109-1, UL 1741, CSA C22.2
1a) The solar charger will limit input power if more PV power is connected.
1b) The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V.
2) A higher short circuit current may damage the solar charger in case of reverse polarity connection of the PV array.
3) Maximum current per MC4 connector is 30A.
4) Equalization is by default disabled.
5) For more information on data communication see the
our website.
6) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels. The MC4 connectors are
internally parallel connected to a single MPPT tracker.
MPPT solar charger manual
Page 60
Technical specifications