cursor  is  indicating  filtration  time)  shall  be  pushed  in  to  confirm  introduced  changes  and  to 

return to 

Menu. 

 button or

 

 

button  (when  a  cursor  is  indicating  minimal  temperature)  shall  be  pushed  in  to  cancel 

introduced changes and to return to 

Menu.

 

,

 button shall be pushed in to exit 

Menu

 

button  shall  be  pushed  in  to  cancel  introduced  setting  and  to  return  to  the  window  in  a 
working mode.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 22. Defreezing

 

and autofiltration parameter setting.

  

 
 

Defreezing

 

function

 

is  turned  on  when  water  temperature  drops  below  minimal 

temperature  and  is  active  until  water  temperature  reaches  maximal  temperature.

 

Function  is 

not turned on (or is cancelled) if water massage, air massage, water heating or Spa preparation 
functions are turned on at the same time. Information on turning on the function is displayed 
in a water function part of the screen in a working mode.  

 

 

 

 

change of 

minimal 

temperature 

 

 

 

 

 

 

 

selection of 

menu position 

 

 

cancellation  

of changes 

 

 

change of 

maximal 

temperature 

 

 

change of 

filtration period 

 

cancellation of changes 

 

 

confirmation  

of changes 

 

 

change of 

filtration time 

 

 

 

 

 

 

confirmation  

of changes 

 

confirmation  

of changes 

 

confirmation  

of changes 

 

 

cancellation  

of changes 

Summary of Contents for Portable SPA Classic

Page 1: ...Portable SPA Classic Operating Instruction...

Page 2: ......

Page 3: ...2 2 2 2 Lighting program selection 12 2 3 Radio receiver optional 12 2 3 1 Turning on the receiver 12 2 3 2 Receiver tuning 13 2 3 3 Volume adjustment 14 2 3 4 Receiver parameter setting 14 2 4 MP3 pl...

Page 4: ......

Page 5: ...information Communication between a system and its user is carried out through a control panel and a remote control After connecting the appliance to the power supply unit the system immediately switc...

Page 6: ...shuts down the hydro massage air massage lightning and the radio or MP3 player when the system is in work mode When the system is in the menu pressing the key closes the menu and brings you back to t...

Page 7: ...in a clock part of the screen When button is pushed in Setting menu will be displayed on the screen Time position shall be selected from Setting menu by buttons When button or button is pushed in a c...

Page 8: ...cursor is indicating a year shall be pushed in to confirm introduced changes and to return to Setting menu When a cursor is indicating a day button shall be pushed in to cancel introduced changes and...

Page 9: ...ble SPA system is equipped with colored lights with single color LEDs or RGB Below is a description of the various work programs of lighting depending on the type of diodes used Single color LEDs No o...

Page 10: ...on as above 23 Red Blue Green Yellow Red blue green and yellow alternating light Light increases and decreases its intensity fluently from minimal to maximal value Simultaneously two next colours shin...

Page 11: ...he form of a current emitted where various cells collide with another This collision results in formation of incalculable colourful vibrations which can be termed as thought The Victory Spa Chromother...

Page 12: ...by buttons If lighting is switched on a selected program is executed immediately and a decision on selecting a suitable program can be made button or button shall be pushed in to confirm a selected pr...

Page 13: ...tation number can be selected by buttons if the screen is in a working mode and a cursor does not indicate station frequency then the buttons are used for automatic station searching A station number...

Page 14: ...ds The receiver is tuning currently into set frequency Manual frequency setting can be useful when station reception is bad when more precise tuning is required or when a station signal is too weak to...

Page 15: ...eudo stereo and Spacial stereo A description of particular values of Sound parameter is presented in a below table Value of Sound parameter Reception of a radio station Audible sound Mono Monophonic M...

Page 16: ...placed MP3 files should be stored in a main catalogue of MMC card Maximal number of files is 254 Higher number can cause wrong operation of a player A player correctly reads out MMC cards with FAT16...

Page 17: ...ws minutes left to turn off water functions Time can be set within 1min 99min Air massage intensity field shows a currently set air massage level which can be set within 5 100 Pushing in the button fo...

Page 18: ...sor to preclude the heater from operation with too low water flow e g in case of failure of the filtration pump The filtration pump is always activated automatically when water or air massage is turne...

Page 19: ...turning off the program will be being executed till the next day If hour of turning on is equal to hour of turning off the program will be executed incessantly During a filtartion program water will...

Page 20: ...to set four daily filtration programs for each weekday button shall be pushed in to start the program edition for a given weekday Cursor position can be changed by buttons A value indicated by the cu...

Page 21: ...eing currently executed is displayed in a water function part of the screen in a working mode Figure 19 Program being currently executed If at present no program is being executed text No program is d...

Page 22: ...return to Menu button when a cursor is indicating ozonization time shall be pushed in to cancel introduced changes and to return to Menu button shall be pushed in to exit Menu button shall be pushed i...

Page 23: ...ve adjustable working parameters A description how to set subject parameters and their influence on operation is presented below When button is pushed in Menu will be displayed on the screen Keeping p...

Page 24: ...n water temperature drops below minimal temperature and is active until water temperature reaches maximal temperature Function is not turned on or is cancelled if water massage air massage water heati...

Page 25: ...ation time parameter Function is turned off in case other function which activates a filtration pump water massage air massage water heating filtration program spa preparation defreezing is activated...

Page 26: ...tem is not possible Power supply should be disconnected and the service should be informed Figure 25 Error window In case of wrong operation of a temperature sensor a suitable message is displayed on...

Page 27: ...27...

Page 28: ...28 Victory Spa Sp Z o o 72 320 Trzebiat w ul Ko obrzeska 24 Tel 48 91 38 730 22 Fax 48 91 38 733 61 kontakt victoryspa pl www victoryspa pl...

Reviews: