background image

11 

 

13 

Turquoise~ 

Turquoise alternating light. Action as above. 

14 

Blue~ -> Green~ 

Blue  and  green  alternating  light.  Light  increases 
and decreases its intensity fluently, from minimal 
to  maximal  value.  When  one  cycle  is  completed 
and  minimum  lighting  intensity  is  reached,  a 
colour changes. 

15 

Blue~ -> Red~ 

Blue and red alternating light. Action as above. 

16 

Green~ -> Red~ 

Green and red alternating light. Action as above. 

17 

Blue~  ->  Green~  -> 
Yellow~ 

Blue,  green  and  yellow  alternating  light.  Action 
as above. 

18 

Red 

-> 

Blue 

-> 

Green~ 

Red,  blue,  and  green  alternating  light.  Light 
increases and decreases its intensity fluently, from 
minimal  to  maximal  value.

 

Simultaneously  two 

next  colours  shine.  When  intensity  of  one  colour 
is  increasing,  intensity  of  another  colour  is 
decreasing.  When  intensity  of  the  first  colour 
reaches  maximum,  the  next  colour  is  starting  to 
shine. 

 

19 

Blue*  ->  Green*  -> 
Red* 

Blue, green and red  flashlight. After a  few quick 
flashes the colour is changed.  

 

DISCLAIMER: 

The Victory Spa Chromotherapy System has been designed to stimulate and aid the reduction 
of varied health related ailments and disorders of the body. Victory Spa chromotherapy works 
by  a  method  of  coloured  light  induction  of  varied  light  sequences  and  bursts  of  light  of 
distinctive  lengths  and  timings.  An  electric  charge  is  produced  due  to  the  influence  of  the 
vibrations  of  cosmic  and  colourful  rays  upon  the  brain  cells.  This  electric  charge  takes  the 
form  of  a  current  emitted  where  various  cells  collide  with  another.  This  collision  results  in 
formation of incalculable colourful vibrations, which can be termed as thought.  

The Victory  Spa  Chromotherapy  System  is  neither  intended  as,  nor  appropriate  as  a 
substitute  for  professional  medical  care  or  medical  consultations.  The  equipment  is  not 
intended  to  diagnose,  treat  or  cure  any  disease  or  condition.  The  equipment  is  not  to  be 
used for diagnosing or treating a health condition, symptoms or a disease. No conclusions 
on  one's  medical  condition  should  be  drawn  without  medical  evaluation  by  an 
appropriately  licensed  physician  or  health  care  professional.  Users  should  always  be 
advised to make informed decisions regarding their health management or if a user has or 
suspects they may have a health problem, they must consult a health care provider prior to 
usage. Due to the variety of programs Victory Spa strongly recommends that the user, prior 
to usage, should always  seek  medical attention  if they  have a disease or health condition 
that  may  be  aggravated  by  the  lighting  programs.  Users  taking  treatment  for  epilepsy 
should  use  extreme  caution  when  looking  at  flashing  lights.  If  the  user  is  taking 
prescription  drugs  warning  labels  must  be  read  to  make  sure  that  no  side  effects  are 
induced if your skin is exposed to bright light. Subject to this, Victory Spa’s liability to the 
incorrect usage in relation to the Victory Spa Chromotherapy System or in connection with 
this disclaimer, Victory Spa will not be liable of a consequential, indirect or special loss or 
damage accordingly. 

 

Summary of Contents for Portable SPA Classic

Page 1: ...Portable SPA Classic Operating Instruction...

Page 2: ......

Page 3: ...2 2 2 2 Lighting program selection 12 2 3 Radio receiver optional 12 2 3 1 Turning on the receiver 12 2 3 2 Receiver tuning 13 2 3 3 Volume adjustment 14 2 3 4 Receiver parameter setting 14 2 4 MP3 pl...

Page 4: ......

Page 5: ...information Communication between a system and its user is carried out through a control panel and a remote control After connecting the appliance to the power supply unit the system immediately switc...

Page 6: ...shuts down the hydro massage air massage lightning and the radio or MP3 player when the system is in work mode When the system is in the menu pressing the key closes the menu and brings you back to t...

Page 7: ...in a clock part of the screen When button is pushed in Setting menu will be displayed on the screen Time position shall be selected from Setting menu by buttons When button or button is pushed in a c...

Page 8: ...cursor is indicating a year shall be pushed in to confirm introduced changes and to return to Setting menu When a cursor is indicating a day button shall be pushed in to cancel introduced changes and...

Page 9: ...ble SPA system is equipped with colored lights with single color LEDs or RGB Below is a description of the various work programs of lighting depending on the type of diodes used Single color LEDs No o...

Page 10: ...on as above 23 Red Blue Green Yellow Red blue green and yellow alternating light Light increases and decreases its intensity fluently from minimal to maximal value Simultaneously two next colours shin...

Page 11: ...he form of a current emitted where various cells collide with another This collision results in formation of incalculable colourful vibrations which can be termed as thought The Victory Spa Chromother...

Page 12: ...by buttons If lighting is switched on a selected program is executed immediately and a decision on selecting a suitable program can be made button or button shall be pushed in to confirm a selected pr...

Page 13: ...tation number can be selected by buttons if the screen is in a working mode and a cursor does not indicate station frequency then the buttons are used for automatic station searching A station number...

Page 14: ...ds The receiver is tuning currently into set frequency Manual frequency setting can be useful when station reception is bad when more precise tuning is required or when a station signal is too weak to...

Page 15: ...eudo stereo and Spacial stereo A description of particular values of Sound parameter is presented in a below table Value of Sound parameter Reception of a radio station Audible sound Mono Monophonic M...

Page 16: ...placed MP3 files should be stored in a main catalogue of MMC card Maximal number of files is 254 Higher number can cause wrong operation of a player A player correctly reads out MMC cards with FAT16...

Page 17: ...ws minutes left to turn off water functions Time can be set within 1min 99min Air massage intensity field shows a currently set air massage level which can be set within 5 100 Pushing in the button fo...

Page 18: ...sor to preclude the heater from operation with too low water flow e g in case of failure of the filtration pump The filtration pump is always activated automatically when water or air massage is turne...

Page 19: ...turning off the program will be being executed till the next day If hour of turning on is equal to hour of turning off the program will be executed incessantly During a filtartion program water will...

Page 20: ...to set four daily filtration programs for each weekday button shall be pushed in to start the program edition for a given weekday Cursor position can be changed by buttons A value indicated by the cu...

Page 21: ...eing currently executed is displayed in a water function part of the screen in a working mode Figure 19 Program being currently executed If at present no program is being executed text No program is d...

Page 22: ...return to Menu button when a cursor is indicating ozonization time shall be pushed in to cancel introduced changes and to return to Menu button shall be pushed in to exit Menu button shall be pushed i...

Page 23: ...ve adjustable working parameters A description how to set subject parameters and their influence on operation is presented below When button is pushed in Menu will be displayed on the screen Keeping p...

Page 24: ...n water temperature drops below minimal temperature and is active until water temperature reaches maximal temperature Function is not turned on or is cancelled if water massage air massage water heati...

Page 25: ...ation time parameter Function is turned off in case other function which activates a filtration pump water massage air massage water heating filtration program spa preparation defreezing is activated...

Page 26: ...tem is not possible Power supply should be disconnected and the service should be informed Figure 25 Error window In case of wrong operation of a temperature sensor a suitable message is displayed on...

Page 27: ...27...

Page 28: ...28 Victory Spa Sp Z o o 72 320 Trzebiat w ul Ko obrzeska 24 Tel 48 91 38 730 22 Fax 48 91 38 733 61 kontakt victoryspa pl www victoryspa pl...

Reviews: