21
mode.
button or
button (in
Monday
window) or
button (in
Sunday
window) shall
be pushed in to return to
Filtration
menu.
button (return to the window in a working
mode) or
button (return to
Menu
) shall be pushed in to exit
Filtration
menu.
button or
,
button shall be pushed in to exit
Menu
and to return to the window in a working mode.
As opposed to daily programs, a weekly program will not be executed (even if it is
active) if hour of turning on and turning off is the same.
If execution time of a program overlaps another one, the programs are executed
according to their order in a list. Daily programs have higher priority than weekly programs
and they are always executed as the first ones.
Information on a program being currently executed is displayed in a water function part of the
screen in a working mode.
Figure 19. Program being currently executed.
If at present no program is being executed, text: „No program” is displayed.
If during program
execution too low water level in the bath is found, the filtration system will be turned off.
Flow water heater
is turned on when water temperature drops half a degree below set
program temperature and is turned off when water temperature is half a degree higher than set
program temperature.
When water temperature exceeds the set temperature one degree program, it will be off
the filtration pump. Filtration pump will be re-activated when the water temperature equals
the set temperature program.
While a program is being executed, ozonator is also turned on, according to the set
working cycle.
Ozonator working cycle setting is presented below.