Victoria-05 Ltd.
12
On this diagram, the user can monitor live data
for the temperature of the smoke sensor and
the speed of the smoke fan.
Rpm of the smoke fan: from 0to 2700
Temperature of the smoke gases: from0°С
to300
о
С. When reaching temperature of
260
о
Сalarm will be triggered.
Four authorization levels to the adjustments of
the controller:
-Installer
-Service technician
-Special settings
-unlocking of the display(password 2468)
The display can be locked by holding for more
than 3 seconds the settings icon in
main menu or in stand-by mode after
10 minutes. Instead of main menu a “lock”
icon will be shown, which have to be touched
and then enter password: 2468.After that
access have to be touched to unlock the
display.
10.2.4. Installer settings.
Types of settings for Installer (entered with installer password)
Factory settings
Vittoria 8
Vittoria 10
Duration
700 sec.
700 sec.
Fan
55 %
55 %
Feed screw
3 sec.
3 sec.
Screw interval
30 sec.
30 sec.
Flame sensor
44
0
C
44
0
C
Initial filling
90 sec.
90 sec.
Second fill
30 sec.
30 sec.
Blowing
60 %
60 %
Duration
120 sec.
120 sec.
Fan
56 %
56 %
Feed screw
2 sec.
2 sec.
Screw interval
20 sec.
20 sec.
Blowing
60 %
60 %
Settings for the three
separate modulation
modes for room
temperature.
Р3
Temperature difference
3
0
C
3
0
C
Fan
48 %
50 %
Feed screw
1,4s
1,7s
Screw interval
3,4 sec.
3,4 sec.
Blowing
100 %
100 %
Р2
Temperature difference
1
0
C
1
0
C
Fan
32 %
34 %
Feed screw
1 sec.
1,3 sec.
Screw interval
4,5 sec.
4,5 sec.
Blowing
85 %
85 %
Р1
Temperature difference
1
0
C
1
0
C
Fan
21 %
21 %
Feed screw
0,8 sec.
0,8 sec.
Screw interval
7 sec.
7 sec.
Blowing
75 %
75 %