16
-
Check sensors;
-
Check and, if necessary, replace the battery on the control panel;
-
Clean and check the electronic control system;
-
Check all electrical cables;
-
Clean the pellet fuel hopper and check auger for loosen screw and the gear motor;
-
Check and if necessary replace the door seal;
-
Make a functional test, insert a small amount of wood pellets in the hopper enough to fill auger. Light a pellet stove
for 10 minutes and shutdown.
It is recommended that the chimney have to be cleaned every three months in intensive use of the pellet stove.
After performing the cleaning procedure, improper attachment of the combustion chamber can seriously harm the
efficiency of pellet stove. Make sure the combustion chamber is properly assembled before starting the pellet stove.
If maintenance procedures are not performed regularly, the guarantee shall be considered invalid!
12.5. Maintenance and control.
The chimney, to which is connected the pellet stove must be cleaned once a year. Check that there is a regulatory standard for
this in your country. If you do not make periodic inspection and cleaning of chimney, the probability of fire is increased many
times. In such incident do the following:
-
Do not extinguish with water;
-
Empty the pellet fuel hopper of wood pellets;
-
Contact the person who has installed the pellet stove, before starting again.
-
13. Possible defects and their causes.
When a problem occurs, pellet stove automatically stops working and shut down procedure is triggered. The display shows the
reason why pellet stove has stopped working. Error messages are described below.
Do not unplug the pellet stove from the main electrical supply during shutdown process!
In case of failure:
-
To restart the pellet stove is necessary to wait the shutdown procedure to be completed. The duration is 10 minutes.
Accompanied with an acoustic signal;
-
Do not switch on again the pellet stove before you check and, if necessary, remove the cause of the problem and
before you clean the combustion chamber.
Possible reasons for blocking: indication and possible solution.
Alarm message
Icon
Designation
Alarm
Description
Pressostat
Pressostat malfunction
The alarm is shown if the pressostat is in open position for
more than 20 seconds. When the alarm is triggered stove
shifts to cleaning and stand-by mode. In stand-by mode the
alarm con not be triggered. When the alarm is triggered
acoustic signal additionally indicates the problem. The icon
is shown on the display. The alarm stops automatically after
1 minute, but the icon does not disappear until it is touched.
The icon cannot be removed until the problem is resolved!
High Temp
High temperature of the
exhaust gasses (above 260
0
С)
To remove the alarm the temperature has to drop below this
value.
No Fire
Failed ignition
The alarm is shown if during operation of the stove, the
smoke outlet sensor detects lower than the set temperature.
When the alarm is triggered stove shifts to cleaning and
stand-by mode.
Power Off
Restarted controller
Fire extinct
extinguished fire
The alarm is shown if there is no fire during second ignition
attempt. When the alarm is triggered stove shifts to cleaning
and stand-by mode.
No Fan
Fan malfunction
The alarm is shown when the rpm sensor does not receive
signal from the fan for 20 seconds.