CUTMASTER 102
Manual 0-4998
INTRODUCTION
2-3
2.05 Input Wiring Specifications
CutMaster 102 Power Supply Input Cable Wiring Requirements
Input volt-
age
Freq
Power Input
Suggested Sizes
Volts
Hz
kVA
I max
I1eff
Fuse (amps)
Flexible Cord
(Min. AWG)
1 Phase
208
50/60
20.6
99
76
100
4 Type W
230
50/60
21.9
95
74
100
4 Type W
460
50/60
27.6
60
46
60
6
3 Phase
208
50/60
17.7
49
38
60
6
230
50/60
17.9
45
36
60
6
380
50/60
18.4
28
22
32
10
400
50/60
18.7
27
22
32
10
460
50/60
23.1
29
22
30
10
600
50/60
22.8
22
17
25
12
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
I1max is taken at TDC rated minimum duty cycle.
I1eff is taken at TDC 100% rated duty cycle.
Summary of Contents for CUTMASTER 102
Page 4: ...This Page Intentionally Blank ...
Page 20: ...CUTMASTER 102 INTRODUCTION Manual 0 4998 2T 4 This Page Intentionally Blank ...
Page 26: ...CUTMASTER 102 INSTALLATION Manual 0 4998 3T 2 This Page Intentionally Blank ...
Page 30: ...CUTMASTER 102 OPERATION Manual 0 4998 4 4 This Page Intentionally Blank ...
Page 46: ...CUTMASTER 102 OPERATION Manual 0 4998 4T 16 This Page Intentionally Blank ...
Page 80: ...CUTMASTER 102 SERVICE Manual 0 4998 5 34 This Page Intentionally Blank ...
Page 91: ...CUTMASTER 102 Manual 0 4998 PARTS LIST 6 9 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Page 105: ...CUTMASTER 102 Manual 0 4998 APPENDIX A 5 This Page Intentionally Blank ...