CUTMASTER 102
OPERATION
Manual 0-4998
4-2
10. Pressure Indicators
PSI
BAR
MAX
MAX
MIN
MIN
80
75
70
65
5.5
85
5.9
90
6.3
5.2
4.8
4.5
Art # A-08170
The Indicators will illuminate ac-
cording to the pressure set by the Pressure Control Knob
(number 4).
4.02 Preparations for Operation
At the start of each operating session:
WARNING
Disconnect primary power at the source before
assembling or disassembling power supply, torch
parts, or torch and leads assemblies.
Torch Parts Selection
Check the torch for proper assembly and appropriate torch
parts. The torch parts must correspond with the type of
operation, and with the amperage output of this Power
Supply (100 amps maximum). Refer to Section 4T.07 and
following for torch parts selection.
Torch Connection
Check that the torch is properly connected. Only Victor
Thermal Dynamics model SL100 / Manual or SL100 / Me-
chanical Torches may be connected to this Power Supply.
See Section 3T of this manual.
Check Primary Input Power Source
1. Check the power source for proper input voltage. Make
sure the input power source meets the power require
-
ments for the unit per Section 2, Specifications.
2. Connect the input power cable (or close the main
disconnect switch) to supply power to the system.
Air Source
Ensure source meets requirements (refer to
Section 2).
Check connections and turn air supply ON.
Connect Work Cable
Clamp the work cable to the workpiece or cutting table.
The area must be free from oil, paint and rust. Connect
only to the main part of the workpiece; do not connect to
the part to be cut off.
Art # A-04509
Power ON
Place the Power Supply ON / OFF switch to the
ON
(up)
position. AC indicator
turns ON. Gas indicator
turns ON if there is sufficient gas pressure for power supply
operation and the cooling fans turn ON.
NOTE
Minimum pressure for power supply operation is
lower than minimum for torch operation.
When the unit is turned ON the cooling fans MOT
1 & MOT 2 will remain OFF. (In earlier units MOT
1 will turn ON for one (1) second and then turn
OFF). The fans will turn ON when a START signal
( Torch Switch, Remote Pendant switch, or CNC
START) is active and will remain ON for ten (10)
minutes after the START signal is removed. If an
over temperature condition occurs, the fans will
continue to run while the condition exists and for a
ten (10) minute period after the condition is cleared.
Set Operating Pressure
1. Place the Power Supply Function Control knob to the
SET
position. Gas will flow.
2. For Standoff cutting, adjust gas pressure from 70 - 85
psi / 4.8 - 5.9 bar (LED's in center of control panel).
Refer to the Standoff chart for pressure setting details.
Summary of Contents for CUTMASTER 102
Page 4: ...This Page Intentionally Blank ...
Page 20: ...CUTMASTER 102 INTRODUCTION Manual 0 4998 2T 4 This Page Intentionally Blank ...
Page 26: ...CUTMASTER 102 INSTALLATION Manual 0 4998 3T 2 This Page Intentionally Blank ...
Page 30: ...CUTMASTER 102 OPERATION Manual 0 4998 4 4 This Page Intentionally Blank ...
Page 46: ...CUTMASTER 102 OPERATION Manual 0 4998 4T 16 This Page Intentionally Blank ...
Page 80: ...CUTMASTER 102 SERVICE Manual 0 4998 5 34 This Page Intentionally Blank ...
Page 91: ...CUTMASTER 102 Manual 0 4998 PARTS LIST 6 9 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Page 105: ...CUTMASTER 102 Manual 0 4998 APPENDIX A 5 This Page Intentionally Blank ...
Page 111: ...This Page Intentionally Blank ...