CUTMASTER 102
SERVICE
Manual 0-4998
5-24
PCB 5 – Q2
Test points located on PCB 5
Meter (+)
Meter (-)
Indication
PRI 4
PMTH 3
Forward Biased Diode
PRI 4
PMTH 4
Reverse Biased Diode
PMTH 3
PRI 4
Reverse Biased Diode
PMTH 4
PRI 4
Forward Biased Diode
PRI 3
PMTH 4
Forward Biased Diode
PRI 3
PMTH 3
Reverse Biased Diode
PMTH 4
PRI 3
Reverse Biased Diode
PMTH 3
PRI 3
Forward Biased Diode
2. If the test reveals a failed component, replace 40Amp
PCB 5.
NOTE
Many of the signals listed in the PCB information to
follow will be low voltage signals that will be in one
of two states: +12VDC (High) or 0VDC (Low) with
respect to PCB common. When a signal name is
preceded by the “/” mark, it denotes that the signal
is an active low. For example:
/OVERTEMP – This signal is normally High but
when an over temperature fault exists, this line will
change state to a Low.
Summary of Contents for CUTMASTER 102
Page 4: ...This Page Intentionally Blank ...
Page 20: ...CUTMASTER 102 INTRODUCTION Manual 0 4998 2T 4 This Page Intentionally Blank ...
Page 26: ...CUTMASTER 102 INSTALLATION Manual 0 4998 3T 2 This Page Intentionally Blank ...
Page 30: ...CUTMASTER 102 OPERATION Manual 0 4998 4 4 This Page Intentionally Blank ...
Page 46: ...CUTMASTER 102 OPERATION Manual 0 4998 4T 16 This Page Intentionally Blank ...
Page 80: ...CUTMASTER 102 SERVICE Manual 0 4998 5 34 This Page Intentionally Blank ...
Page 91: ...CUTMASTER 102 Manual 0 4998 PARTS LIST 6 9 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Page 105: ...CUTMASTER 102 Manual 0 4998 APPENDIX A 5 This Page Intentionally Blank ...
Page 111: ...This Page Intentionally Blank ...