CUTMASTER 102
Manual 0-4998
SERVICE
5-27
J2-34 For Factory Use
M-L
J2-35 +3.3VDC M-L
J2-36 TXD M-L
J2-37
RXD
L-M
J2-38 Common M-L
J2-39
D
M-L
J2-40
Not Used
J3-1 /230VAC
J3-2 Common
J4-1 3.3VDC
J4-2 TXD
J4-3
RXD
J4-4
Common
J4-5
D
J5-1
+12VDC
J5-2
Not used
J5-3
/SOLENOID
J6-1
24VAC Supply for W1
J6-2
24VAC Return
J7-1 +12VDC
J7-2 /FAN
J8
Not Used
J9-1 /PIP
J9-2 Common
J9-3
/TORCH SWITCH (START)
J9-4 Common
J9-5
Automation Torch solenoid
24VAC supply
J9-6
Not Used
J9-7
Automation Torch solenoid
24VAC return
J10-1
/OK-TO-MOVE
J10-2
Not used
J10-3
/OK-TO-MOVE
J10-4
Not used
J10-5 Common
J10-6 Common
J10-7 +12VDC
J10-8 /START (Remote Pendant / CNC Signal)
J11 N/A
J12-1 +12VDC
J12-2 /460VAC
J12-3 /230VAC
J13-1
/OVERTEMP
J13-2 /FAN_ON
J13-3
/CSR
J13-4 CUR_SET
J13-5
MAIN_PCB_ID
J13-6 Common
MAIN PCB 1 LED INDICATORS
D59 PCR Indicates Pilot IGBT gate signal is ON
D78 CSR Indicates cutting arc has been established
MAIN PCB 1 TEST POINTS
+12V1 +12VDC
+12V2 +12VDC
+48V1 +48VDC
+48V2 +48VDC
AC1
AC Input
AC2
AC Input
AC3
AC Input
CHOKE1
Negative DC output to L1
ELECTRODE1
Negative DC output to torch
GND1 Common
GND2 Common
I_DMD1
Current Demand Signal
1.5VDC during Pilot
1.2-4 VDC During Cut
PRI_1 (A)
IGBT Bank A Output to T1
PRI_2 (B
)
IGBT Bank A Output to T1
PRI_3 (D)
IGBT Bank B Output to T1
PRI_4 (C)
IGBT Bank B Output to T1
SEC1 T1 Secondary
SEC2 T1 Secondary
TP1
Capacitor Bank A+
TP2
Capacitor Bank A+
TP3
Capacitor Bank B+
TP4
Capacitor Bank B+
TP5
Capacitor Bank A-
TP6
Capacitor Bank A-
TP7
Capacitor Bank B-
TP8
Capacitor Bank B-
TIP1
Positive Tip DC Output
-V_OUT1
Negative DC output
WORK1
Positive DC output
Summary of Contents for CUTMASTER 102
Page 4: ...This Page Intentionally Blank ...
Page 20: ...CUTMASTER 102 INTRODUCTION Manual 0 4998 2T 4 This Page Intentionally Blank ...
Page 26: ...CUTMASTER 102 INSTALLATION Manual 0 4998 3T 2 This Page Intentionally Blank ...
Page 30: ...CUTMASTER 102 OPERATION Manual 0 4998 4 4 This Page Intentionally Blank ...
Page 46: ...CUTMASTER 102 OPERATION Manual 0 4998 4T 16 This Page Intentionally Blank ...
Page 80: ...CUTMASTER 102 SERVICE Manual 0 4998 5 34 This Page Intentionally Blank ...
Page 91: ...CUTMASTER 102 Manual 0 4998 PARTS LIST 6 9 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Page 105: ...CUTMASTER 102 Manual 0 4998 APPENDIX A 5 This Page Intentionally Blank ...
Page 111: ...This Page Intentionally Blank ...