TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Pipe flare is excessive.
Pipe is “over-tracking”.
Refer to the Operating and Maintenance Instructions Manual for
the applicable tool being used to groove the pipe.
Pipe height adjustment is too high.
Roll grooving tool is tilted forward.
Pipe is out of specification.
Pipe face is excessively scuffed. Pipe is “over-tracking”.
Pipe will not stay in roll
grooving tool.
Insufficient pipe tracking angle.
Pipe is rotating in the wrong direction.
Pipe is not square cut.
Back end of pipe is above level.
Roll grooving tool is tilted forward.
In the event of tool malfunction outside the scope of the troubleshooting section, contact Victaulic for
assistance.