XX028-06-00 Rev 1002 Surveyor4 Fixed-Position Camera Dome
Technical Information
••
15
Technical Information
ELECTRICAL
Input Voltage:
13 – 28 VAC (24 VAC nominal), nonisolated. (Nonisolated camera input requires
an isolated power supply; see Installation section.)
Current Rating:
300 mA at 24 VAC.
Power Consumption:
7.2 W.
Heat Equivalent:
0.4 btu/min (0.1 kg-cal/min).
Note: These figures represent the conversion of 100% of the electrical energy to heat.
Actual percentage of heat generated will be less and will vary from product to product.
These figures are provided as an aid in determining the extent of cooling required for
an installation.
Maximum Operating
Distance:
Voltage
Wire
Gauge
ft (m)
20
18
16
14
12
24 VAC
1830 (550)
2860 (870)
4580 (1400)
7300 (2225)
11,450 (3490)
Connectors:
Power: 3-pin terminal.
Video: BNC.
Radio Frequency
Emission Rating:
FCC Class A.
CAMERA/LENS
Specifications:
Refer to Table 3.
OPERATIONAL
Tilt and Horizontal
Adjustment:
4 axis adjustment, pan, tilt, vertical height of camera/lens and
roll (lens may be rotated on its axis 360°).
MECHANICAL
Application:
Indoor.
Mounting:
In-ceiling.