background image

XX028-06-00 Rev 1002 Surveyor4 Fixed-Position Camera Dome 

Installation  

••

  7 

 

 

Figure 3 

Enclosure/Camera Assembly Components (Inside View) 

 

 

 

Figure 4 

Camera Orientation (Color Camera) 

Summary of Contents for Surveyor 4

Page 1: ...en designed to be used in life critical situations and must not be used for this purpose WARNING To reduce a risk of fire or electric shock do not expose this product to rain or moisture Copyright 200...

Page 2: ...XX028 06 00 Rev 1002 Surveyor4 Fixed Position Camera Dome Contents ii...

Page 3: ...ation 3 Unpacking and Inspection 3 Inspection for Visible Damage 3 Inspection for Concealed Damage 3 Surveyor4 Dome Components 3 Mounting the Unit 4 Camera Lens Adjustments 8 Final Installation 10 Ope...

Page 4: ...ii Quick Installation XX028 06 00 Rev 1002 Surveyor4 Fixed Position Camera Dome Quick Installation...

Page 5: ...model is available that offers twisted pair video connection A UTP receiver is required for twisted pair configurations Refer to Table 1 for complete model descriptions The camera position is adjustab...

Page 6: ...ked lower dome NTSC coaxial cable video S4 CA36C 7820 01 1 3 in color camera and 2 6 6 mm varifocal autoiris lens 24 VAC 4 inch smoked lower dome PAL coaxial cable video S4 CH36 7821 00 1 3 in high re...

Page 7: ...yor4 camera dome units consist of an enclosure an adjustable camera mounting bracket a shroud and a smoked lower dome It includes a 4 x 4 electrical box for cable routing and mounting The camera lens...

Page 8: ...for the cabling requirements and route the cables through these hole s 3 Compress the mounting bracket flush to the electrical box and insert the box into the hole in the ceiling The right angle brack...

Page 9: ...ts between cameras causing a base frequency 50 Hz 60 Hz distortion on the video signal It affects the video by causing horizontal line distortion more commonly known as hum bars To eliminate ground lo...

Page 10: ...ening distorts the enclosure making the installation of the lower dome difficult 11 Connect the safety cord lanyard on the lower dome to one of the holes provided in the enclosure with the screw that...

Page 11: ...XX028 06 00 Rev 1002 Surveyor4 Fixed Position Camera Dome Installation 7 Figure 3 Enclosure Camera Assembly Components Inside View Figure 4 Camera Orientation Color Camera...

Page 12: ...ization As an example equipment like a video switcher unit uses the camera s line lock to reduce video jump on its monitor during camera switching The adjustment for the line lock V phase is accessed...

Page 13: ...h 2 is functional which allows the selection of internal autoiris left position or external autoiris right position Do not adjust this DIP switch if using a manual lens Lens Autoiris Adjustment The le...

Page 14: ...nut The picture may be squared up by rotating the camera about its own axis up to 360 roll adjustment Note After all adjustments are made be sure to tighten all bracket screws Final Installation When...

Page 15: ...me s interior they should be removed with clean dry air pressure compressed air cans 3 If spots streaks or stains appear on the interior or exterior they can be removed with a solution of isopropyl al...

Page 16: ...countries in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following inform...

Page 17: ...ing 95 or better coverage Cable Types The most commonly used cable types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical characteristics some of which are no...

Page 18: ...l and other safety requirements Make sure the pair of wires carrying the video signal is sent as a twisted pair the blue white white blue wires twisted together as a pair not a split pair blue white c...

Page 19: ...tual percentage of heat generated will be less and will vary from product to product These figures are provided as an aid in determining the extent of cooling required for an installation Maximum Oper...

Page 20: ...eter 5 25 in 133 mm Total width of electrical box 4 75 in 121 mm Weight Approximately 3 0 lb 1 4 kg Construction Plastic and steel Finish Black enclosure smoked gray tint lower dome ENVIRONMENTAL Oper...

Page 21: ...2 1 interlace NTSC PAL Color 330 0 056 0 6 At 40 IRE f 1 2 1 60 1 50 100 000 48 dB AGC off S4 CH36 S4 CH36C 1 3 CCD 2 1 interlace NTSC PAL Color 460 0 019 0 2 At 25 IRE f 1 2 1 60 1 50 1 100 000 48 dB...

Page 22: ...CCTV 2288 Infofax 800 287 1207 Vicon Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Z...

Reviews: