XX077-00-00 Rev 1201 Surveyor2000-MSH Maximum Security Housing
Installation
••••
7
CONNECTOR/PIN
NUMBER
CONNECTOR TYPE
CONNECTOR/PIN LABEL
SIGNAL NAME
BNC (female)
VIDEO (J1)
J1
VIDEO
Video output
TERMINAL BLOCK
POWER (TB1)
TB1-1
H
Hot
TB1-2
N
Neutral
TB1-3
No connection
RJ-45
ALARM (J2)
J2-1
ALARM1
Alarm input 1
J2-2
VSSA
Ground
J2-3
ALARM2
Alarm input 2
J2-4
VSSA
Ground
J2-5
ALARM3
Alarm input 3
J2-6
VSSA
Ground
J2-7
ALARM4
Alarm input 4
J2-8
VSSA
Ground
TERMINAL BLOCK
COMM (TB3)
TB3-1
VSSA
Ground
TB3-2
RO+
Response out +
TB3-3
CI-
Command in -
TB3-4
RO-
Response out -
TB3-5
CI+
Command in +
RJ-45
COMM/RELAY (J3)
J3-1
CI+
Command in +
J3-2
RELAY NC
Relay, normally closed
J3-3
VSSA
Ground
J3-4
RO-
Response out -
J3-5
CI-
Command in -
J3-6
RELAY C
Relay, common
J3-7
RELAY NO
Relay, normally open
J3-8
RO+
Response out +
Table 4
Electrical Connections
7.
Configure communication and address DIP switches. For example:
DIP SWITCH S1 (Address 1):
1 - ON, 2 - OFF, 4 - OFF, 8 - OFF, 16 - OFF, 32 - OFF, 64 - OFF, 128 - OFF
DIP SWITCH S2 (typical configuration):
1 - ON (NTSC), 2 - OFF (VPS), 3 - OFF (DUPLEX), 4 - OFF (RS-422), 5 through 8 - OFF (not used)
For a detailed description of DIP switch configuration, refer to the Configuration section of the
Surveyor2000 Installation & Operation Manual XX031.
8.
Attach Lower Dome using previously removed nine (9) Tamperproof Screws.
9.
Installation is complete.