XX077-00-00 Rev 1201 Surveyor2000-MSH Maximum Security Housing 

Cable Recommendations  

••••

  10 

Cable Recommendations 

Coaxial Cable 

Caution: Careful selection of the proper cable is essential to obtain the best performance from this 

equipment. Vicon assumes no responsibility for poor performance when cables other than those 
recommended are installed. In all cases, coaxial cable impedance should be 75 ohms. 

 

Materials 

Use only cable with a pure copper center conductor. Do not use cable with either a copper-plated steel or an aluminum 
center conductor because these do not transfer signals effectively in the frequency range used in CCTV networks. A 
center conductor with low DC resistance is required for effective CCTV operation. Solid-core bare copper conductor is 
best suited to video applications, except where flexing occurs. If the coaxial cable will be subjected to flexing during 
normal use, select a cable with a stranded center conductor. The preferred dielectric material is cellular (foam) 
polyethylene. It has better electrical characteristics than solid polyethylene, but is more vulnerable to moisture. Therefore, 
use only solid polyethylene dielectric cable with a heavy exterior insulation in applications subject to moisture. The shield 
must be copper braid providing 95% or better coverage. 
 

Cable Types 

The most commonly used cable types are RG-59/U and RG-11/U. Each is actually a family of cables with widely varying 
electrical characteristics, some of which are not suitable for CCTV applications. Choose a cable type by referring to the 
characteristics and maximum distances listed below. The maximum distance for best picture refers to the distance 
between the camera and the unit The characteristics of the cables in this table should be used as a guideline when cables 
other than Belden are used. Materials and construction must follow the guidelines above. Note that “BC” refers to bare 
copper and “TC” refers to tinned copper. 
 

Recommended Coaxial Cable Types 

Cable 

Type 

Belden 

Type No. 

Alpha 

Type No. 

West Penn 

Type No. 

Type Center 

Conductor 

Type Shield and 

% Coverage 

DC Resistance 
ohms per 1000 

feet (km) 

RG-11/U 

8213 

9847 

811,4811 

14 Solid BC 

BC braid (95%) 

2.6 (8.5) 

RG-6/U 

9248 

9804C 

806,4806 

18 Solid BC 

Foil + 61% TC 
braid (100%) 

7.5 (24.6) 

RG-59/U 

8281 

9803 

815 

20 Solid BC 

2 TC braids (96%) 

9.9 (32.5) 

RG-59/U 

9259 

---- 

816 

22 Stranded BC 

BC braid (95%) 

15.0 (49) 

RG-59/U 

9659 

---- 

---- 

22 Stranded BC 

BC braid (95%) 

15.0 (49) 

 

Picture Quality vs. Cable Length 

Maximum Cable Run* ft (m) 

Picture Quality 

RG-59/U RG-6/U RG-11/U 

Usable picture 

1100 (350) 

1500 (450) 

2400 (750) 

Clean picture 

820 (250) 

1000 (300) 

1600 (500) 

Best picture 

400 (120) 

530 (160) 

820 (250) 

         * Longer cable runs may produce a dim, faint picture. Use a Vicon Video Amplifier to obtain a usable 

picture for long cable runs. 

Usable Vicoax Signal vs. Cable Length 

Maximum Cable Length ft (m) 

RG-59/U RG-6/U  RG-11/U 

Usable Vicoax signal 

1500 (450) 

1500 (450) 

1500 (450) 

 

 

Summary of Contents for Surveyor 2000-MSH

Page 1: ...stem has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2001 Vicon Industries Inc All rights reserved Product specifications subject to change...

Page 2: ......

Page 3: ...rveyor2000 MSH Maximum Security Housing Components 3 Unpacking and Inspection 3 Accessory Kit 3 INSTALLATION 6 Mounting the Unit 6 OPERATION 8 MAINTENANCE 8 Care and Cleaning of Clear Acrylic Domes 8...

Page 4: ...XX077 00 00 Rev 1201 Surveyor2000 MSH Maximum Security Housing Quick Installation 2 Quick Installation Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N...

Page 5: ...ing Components The MSH consists of a thick steel Enclosure a sealed Lower Dome assembly and mounting studs for the Surveyor2000 Camera Drive In addition the Housing provides outside holes for external...

Page 6: ...615 00 1 4 in monochrome camera EIA version 22x zoom high resolution camera lower polycarbonate dome mounting bracket not included S2000 MW22C MSH 7615 01 1 4 in monochrome camera CCIR version 22x zoo...

Page 7: ...XX077 00 00 Rev 1201 Surveyor2000 MSH Maximum Security Housing Introduction 5 Figure 1 Exploded View...

Page 8: ...lag type screws or bolts with lock and flat washers Choose one of the two available four 4 hole mounting patterns Lift the Housing to the Mounting Bracket and connect it using the four 4 pre installed...

Page 9: ...TB3 5 CI Command in RJ 45 COMM RELAY J3 J3 1 CI Command in J3 2 RELAY NC Relay normally closed J3 3 VSSA Ground J3 4 RO Response out J3 5 CI Command in J3 6 RELAY C Relay common J3 7 RELAY NO Relay no...

Page 10: ...ry pressurized air 3 If spots streaks or stains appear on the exterior they can be removed with a solution of mild soap or isopropyl alcohol and water using a lint free soft paper towel Dry with clean...

Page 11: ...from countries in Europe contact Vicon Europe Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following inform...

Page 12: ...types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical characteristics some of which are not suitable for CCTV applications Choose a cable type by referring...

Page 13: ...vidually shielded twisted pair in a single jacket This configuration is the most convenient for RS 422 RS485 applications Single twisted pair is also a suitable cable Choose a Belden cable type by ref...

Page 14: ...luded Power Consumption 48 0 W nominal heater included Heat Equivalent 2 7 btu min 0 6 kg cal min Note These figures represent the conversion of 100 of the electrical energy to heat Actual percentage...

Page 15: ...rogramming is done in real time with joystick and push buttons Preset Solving Speed 1 second nominal Preset Repeatability 0 3 maximum Alarm Capabilities 4 alarm inputs Individual input enable disable...

Page 16: ...n composite video signal automatically detected upon power up RS 485 protocol utilizes full tri state outputs for daisy chain capability Control Display On screen menu driven system allowing full conf...

Page 17: ...sized to accommodate provided 3 8 in 9 5 mm hardware Lower Dome Clear Acrylic impact resistant Dimensions See Table 6 and Figure 2 Configuration Width W in mm Height H in mm Depth D in mm Housing Alon...

Page 18: ...ssembly 40 to 105 F 40 to 40 5 C Outdoors with sun exposure with Heater Blower Assembly and Sunshield 40 to 122 F 40 to 50 C Note The Sunshield cannot be used with the S2000 MSH CM Ceiling Mount Brack...

Page 19: ...XX077 00 00 Rev 1201 Surveyor2000 MSH Maximum Security Housing Technical Information 17 NOTES...

Page 20: ...ope Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780 Fax 322 712...

Reviews: