background image

XX077-00-00 Rev 1201 Surveyor2000-MSH Maximum Security Housing 

  

••••

  11 

Twisted-Pair Cable 

CAUTION:  Careful selection of the proper cable is essential to obtain the best performance from this 

equipment. Vicon assumes no responsibility for poor performance when cables other than 
those recommended are installed. 

 

Materials

 

 
Use a pure copper stranded conductor with or without a tin plating to obtain a low DC resistance. Do not use cable with 
either a steel or an aluminum stranded conductor because these do not transfer signals effectively for long distances. The 
preferred insulation and cable jacket is Polyvinyl chloride (PVC). It has better electrical characteristics than polyethylene 
and resists flames, sunlight and most solvents, but is more vulnerable to moisture. 
 

Cable Types 

 
The most commonly used cable types are dual individually-shielded, twisted pair in a single jacket. This configuration is 
the most convenient for RS-422/ RS485 applications. Single twisted pair is also a suitable cable. 
 
Choose a Belden cable type by referring to the characteristics and maximum distances listed below. The maximum 
distance for the most reliable digital control refers to the distance between the CPU/Keypad and the Camera Dome 
Assembly. The characteristics of the cables in Table 3 should be used as a guideline when cables other than Belden are 
used. Materials and construction must follow the guidelines above. 
 

Recommended Individually-Shielded, Twisted-Pair Cable Types

 

 

¹

Datalene is a Registered Trademark of Belden. 

 

CABLE 

TYPE

WIRE SIZE 

(AWG)

INSULATION 

MATERIAL

JACKET 

MATERIAL

DISTANCE ft (m) 

max.

NUMBER OF 

TWISTED PAIRS

Belden 9406

22

PVC

PVC

5000 (1500)

2

Belden 9402

20

PVC

PVC

5000 (1500)

2

Belden 8723

22

Polypropylene

PVC

8000 (2400)

2

Belden 8162

24

Datalene¹

PVC

15000 (4600)

2

Belden 9729

24

Datalene¹

PVC

15000 (4600)

2

Belden 9182

22

Datalene¹

PVC

25000 (7600)

1

Summary of Contents for Surveyor 2000-MSH

Page 1: ...stem has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2001 Vicon Industries Inc All rights reserved Product specifications subject to change...

Page 2: ......

Page 3: ...rveyor2000 MSH Maximum Security Housing Components 3 Unpacking and Inspection 3 Accessory Kit 3 INSTALLATION 6 Mounting the Unit 6 OPERATION 8 MAINTENANCE 8 Care and Cleaning of Clear Acrylic Domes 8...

Page 4: ...XX077 00 00 Rev 1201 Surveyor2000 MSH Maximum Security Housing Quick Installation 2 Quick Installation Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N...

Page 5: ...ing Components The MSH consists of a thick steel Enclosure a sealed Lower Dome assembly and mounting studs for the Surveyor2000 Camera Drive In addition the Housing provides outside holes for external...

Page 6: ...615 00 1 4 in monochrome camera EIA version 22x zoom high resolution camera lower polycarbonate dome mounting bracket not included S2000 MW22C MSH 7615 01 1 4 in monochrome camera CCIR version 22x zoo...

Page 7: ...XX077 00 00 Rev 1201 Surveyor2000 MSH Maximum Security Housing Introduction 5 Figure 1 Exploded View...

Page 8: ...lag type screws or bolts with lock and flat washers Choose one of the two available four 4 hole mounting patterns Lift the Housing to the Mounting Bracket and connect it using the four 4 pre installed...

Page 9: ...TB3 5 CI Command in RJ 45 COMM RELAY J3 J3 1 CI Command in J3 2 RELAY NC Relay normally closed J3 3 VSSA Ground J3 4 RO Response out J3 5 CI Command in J3 6 RELAY C Relay common J3 7 RELAY NO Relay no...

Page 10: ...ry pressurized air 3 If spots streaks or stains appear on the exterior they can be removed with a solution of mild soap or isopropyl alcohol and water using a lint free soft paper towel Dry with clean...

Page 11: ...from countries in Europe contact Vicon Europe Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following inform...

Page 12: ...types are RG 59 U and RG 11 U Each is actually a family of cables with widely varying electrical characteristics some of which are not suitable for CCTV applications Choose a cable type by referring...

Page 13: ...vidually shielded twisted pair in a single jacket This configuration is the most convenient for RS 422 RS485 applications Single twisted pair is also a suitable cable Choose a Belden cable type by ref...

Page 14: ...luded Power Consumption 48 0 W nominal heater included Heat Equivalent 2 7 btu min 0 6 kg cal min Note These figures represent the conversion of 100 of the electrical energy to heat Actual percentage...

Page 15: ...rogramming is done in real time with joystick and push buttons Preset Solving Speed 1 second nominal Preset Repeatability 0 3 maximum Alarm Capabilities 4 alarm inputs Individual input enable disable...

Page 16: ...n composite video signal automatically detected upon power up RS 485 protocol utilizes full tri state outputs for daisy chain capability Control Display On screen menu driven system allowing full conf...

Page 17: ...sized to accommodate provided 3 8 in 9 5 mm hardware Lower Dome Clear Acrylic impact resistant Dimensions See Table 6 and Figure 2 Configuration Width W in mm Height H in mm Depth D in mm Housing Alon...

Page 18: ...ssembly 40 to 105 F 40 to 40 5 C Outdoors with sun exposure with Heater Blower Assembly and Sunshield 40 to 122 F 40 to 50 C Note The Sunshield cannot be used with the S2000 MSH CM Ceiling Mount Brack...

Page 19: ...XX077 00 00 Rev 1201 Surveyor2000 MSH Maximum Security Housing Technical Information 17 NOTES...

Page 20: ...ope Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780 Fax 322 712...

Reviews: