Chapter 5
G0201WAD3EN
27
electronic control system INFOBALE
5.4 Calibration of the bale diameter
sensor
1
Open the tailgate and position the stop pin in the lower
hole in the sidewall!
2
Then lower the tailgate pressureless (floating position)
till the tensioner arm rests on the stop pin. This is the
basic position for calibration.
3
Set toggle switch (2) to WD (= RV 1601) or WA (=
RV 1901)
4
Push reset button (5) on the machine control box while
starting the system. Keep the reset button pushed in till a
beep signal sounds. This may long about 15 seconds! If
the calibration has failed a beep signal sounds for 10
seconds!
5
Then release the reset button: calibration is ready now!
6
When the calibration is finished, remove the stop pin
and reposition it into its retaining hole.
5.5 Alarm warnings
Alarm
Cause
Times
Lasts (sec)
Repeats
Quick beep
-
Failure (e.g. tailgate lock open,
net not fed in).
-
Till failure has been removed.
Quick beep.
-
Max. bale diameter has been
reached.
-
6
-
5 sec.
Long beep.
-
Bale growth sensor broken.
-
10 sec + LED does not burn.
-
every baling
cycle after
closing
tailgate.
Quick inter-
rupted
beeps
-
No twine tie available (just net wrap);
although twine tie has been selected.
-
Twine tie sensor gives fault value.
-
10 sec.
-
every baling
cycle after
closing
tailgate.
W
A0054
SOS
000000
PROG
W
A0213
1
5
6
2
3
4