7. Confirm the current message.
The machine is ready for operation.
6.3 Sw itching off the machine
DANGER
Danger of an electric shock if
unplugging the power cable
before switching off the machine
If you unplug the power cable while the main power
switch is still in “ON” position, residual voltage in the
power cable may cause you to suffer from an electric
shock.
Before
unplugging the power cable, switch off the
machine at the main power switch.
To switch off the machine, do the following:
1. Ensure that the working chamber is clean.
2. Switch off the machine at the main power switch.
3. (Optional) Unplug the power cable.
4. (Optional) Switch off the main power switch of
your workstation / facility.
6.4 Mounting & removing blanks
The machine can process the following blanks:
n
Discs with a diameter of 98.5 mm – 98.8 mm
n
Blocks, max. size: 45 x 20 x 20 mm (L/D/H)
*
n
Prefabricated abutments
*
*
requires extra equipment
You can obtain extra equipment from customer
service.
Tools used for cobalt-chrome blanks are shorter
than tools for other materials. Only cobalt-
chrome blanks with a
maximum thickness of
18 mm
can be machined.
How to mount the different blank types
Blank type
Holder
required?
How to mount
Discs
No
Discs >> Blank frame
*
>>
Blank magazine
Blocks
Yes
Blocks >> Block holder >>
Blank magazine
Prefabricated
abutments
Yes
Prefabricated abutments
>> Prefabricated abut-
ment holder >> Blank
Blank type
Holder
required?
How to mount
frame
*
>> Blank magazine
*
8 blank frames provided with the machine
S5 – Operation: Preparing jobs
EN 27
Original Operating Instructions: S5
Version: 12/15/2021