80
7 Winter storage procedure
4 Raw water cooling system
• Close the sea cock.
• Remove the lid of the water strainer.
• If necessary, clean the raw water strainer.
• Connect the raw water intake to a fresh wa-
ter (tap water) supply or a tank containing
fresh water. Open the tap and allow the en-
gine to idle for at least 5 minutes to remove
any salt and contamination from the raw
water cooling system.
Make sure that there is a sufficient supply
of water to prevent the engine from over-
heating.
• Stop the engine and close the sea cock.
• The raw water system must be protected in
areas where the temperature drops to be-
low zero during the winter.
Pour 1 litre (1/4 gallon) of anti-freeze (prefer-
ably a non-toxic biodegradable anti-freeze)
into the water strainer and run the engine
until the anti-freeze has disappeared into
the cooling system.
t
ip
!
Combine flushing the raw water circuit
with fresh water with running the en-
gine with the protective fuel mixture,
see ‘Winter storage procedure - Protec-
tive fuel mixture’
Heat exchanger
Only clean the heat exchanger if this is
absolutely necessary, see page
72
.
Raw water pump
Check the impeller of the raw water
pump at least once every two years, see
page
64
.
VD00125
VD00801
n
ote
Only engines with intercooling!