79
6 Maintenance
Raw water pump inspection
Every 1000 operating hours.
60 Re-install the impeller
• The impeller should be lubricated with
glycerin or a non-petroleum based lubri-
cant such as a silicone spray before fitting it
into the impeller housing.
• Fit the impeller to the pump shaft. (if an
existing impeller is re-used, install it in the
same position as removed).
61 Reinstall the pump cover
• Reinstall the cover with a
new
O-ring.
• Check the water filter and open the sea
cock.
For
O-ring
art. code
see page
VD00004
VD00961