118
Model
:
DT4.70
DTA4.85
Oil lubrication system
Oil capacity, max.
:
without oil filter
:
6.0 litres (10.6 UK pt, 12.7 US pt)
with oil filter
:
6.3 litres (11.1 UK pt, 13.3 US pt)
Oil Filter
:
08-00085
Oil temperature in sump
:
max. 120°C (248°F)
Cooling system
Capacity
:
8.0 litres (14.1 UK pt, 16.9 US pt)
Thermostat
:
opening at 82°C (180°F), fully opened at 97°C (207°F)
Coolant pump,
Flow at max. engine rpm
:
135 litres/min (29.7 UK gal/min, 35.7 US gal/min)
Raw water pump,
Flow at max. engine rpm
:
80 litres/min (17.6 UK gal/min, 21.1 US gal/min)
Total head at max. flow
:
2 metre (6’ 7”) H2O
Impeller
:
STM8074
Inlet connection for hose
:
28 mm (1 1/8") I.D.
Heater supply connection
:
16 mm (5/8") I.D.
Heater return connection
:
16 mm (5/8") I.D.
10 Technical data