To ensure reliable functioning of the SmartFork
®
Secure system, a gap of
at least 3 cm between the individual loads in the block storage must be
ensured.
When both fork arms are equipped with the VETTER SmartFork
®
Secure
application, the first VETTER SmartFork
®
to enter the load is displayed
when approaching at an angle.
All settings for the VETTER SmartFork
®
Secure application are in the
supplied documents for the VETTER EasySecure LED display.
5.6
VETTER SmartFork
®
EasySecure
WARNING!
Risk of injury from tipping or slipping load!
Incorrect lifting of loads could cause the load to tip or slip and cause
serious injuries.
Observe the following to ensure reliable functioning of the Smart
Fork
®
Easy
Secure
application:
–
Ensure that the sensors on the upper side of the Smart
Fork
®
Easy
Secure
application are never covered and are always kept
clean.
–
Ensure that non-reflective materials, e.g. black plastic pallets do not
prevent safe functioning.
–
Ensure that cover foils such as wrap-around or shrink wrap in the
area of the pallet pockets do not disrupt the system and do not pre-
vent safe functioning.
Fig. 25: VETTER SmartFork
®