31
■
Troubleshooting
Troubleshooting
Phenomenon
Cause
Measure
It is not possible to eliminate
static electricity.
The electrode is extremely dirty.
Clean the discharge needle.
Worn discharge needle.
Replace the discharge needle.
High voltage transformer is in
failure.
Contact your local dealer for repair service.
No LED light-up
Bad contact of motor
cartridge.
Remove the cartridge and mount it again.
Motor cartridge worn.
Replace motor cartridge.
No air supplies.
Check air valve / regulator.
Blinking green LED
Bad contact of motor
cartridge.
Remove the cartridge and mount it again.
Motor cartridge worn.
Replace motor cartridge.
Body housing cracking by too
much tighten or shock.
Check the housing and contact your local
supplier if any crack is found.
LED yellow even high air
pressure and perform regulator
adjust
Inner valve choking.
Please contact your local
supplier
.
LED red even low air pressure
and perform regulator adjust
Inner valve failure.
Blinking red LED
High voltage transformer
failure.
Sounds from inside and feel air
leaking
Inner tube break.
Harder trigger
Initial grease dried up (by the
quality of supplied air).
No air blow
Inner mechanical valve
failure.
Trigger does not come back
■
Storage
Caution
PROHIBITED
Do not store the G-9 in the following places. Adverse environments can cause product
breakdown;
●
Where exposed to marked vibrations or shock;
●
Where temperature and humidity are outside specified ranges;
●
Where dewing occurs;
●
Where temperature fluctuates sharply;
●
Where there is the possibility of ignition or explosion of flammable solvents, dust, etc.;
●
Where there is heavy dirt, dust, or smoke;
●
Where possibly wet by water, oil , chemicals, etc.;
●
Where strong electric or magnetic fields are generated.