To place and remove a handset

Place

#1 Place the handset on the   

  base of the cradle  

#2 Snap in horizontally.

Remove

Slide the handset 

upwards.

To connect power to a handset

 H1 
 

1.  Connect the H1 plug to the 

   

H1 Bulkhead Connector.

  2.   Tighten the plug lock ring 

   

(clockwise one quarter turn)  

   

for a secure and  watertight 

   connection.

 H1P
 

1.  Place the H1P into the charging cradle.

1. BASE, SOCKET & NUT ASSEMBLY

FRONT ON ANGLE AS CRADLE ABOVE

Note - Before first time use ensure the H1P is charged.

#1 Place

#2 Snap

Summary of Contents for CORTEX H1

Page 1: ...1 H1 INSTALLATION GUIDE H1 TETHERED HANDSET H1P PORTABLE HANDSET ...

Page 2: ... 10 To install a Bulkhead Connector 11 To connect power to a handset 12 To place and remove a handset 12 Turning a handset ON 13 To connect a handset to an M1 14 Handset connection FAQs 15 To connect mobile devices to an M1 15 To program your MMSI number 16 To program your ATIS id 17 Handset care 18 Handset use 18 Dimensions and Specifications 19 Warnings 20 Compliance 21 Warranty 22 Index ...

Page 3: ...get data and vessel instrumentation manage and monitor alarms and configure the remote vessel monitoring The H1 version has a spiral tether connected to the vessel s 12V or 24V power DC via a bulkhead plug and socket The H1P includes a robust surface mount cradle to secure the handset in a fixed location and identify it as a VHF radio The H1P is designed for freedom of movement on board The H1P ha...

Page 4: ...OTE Never make a distress call if your vessel or a person is not in an emergency situation A distress call should only be made when immediate help is needed A distress call should be initiated if in the opinion of the captain the vessel and or a person is in distress requiring immediate assistance To make an Undesignated Distress DSC Call Distress DSC Emergency Calls ...

Page 5: ... latitude and longitude Or by bearing true or magnetic state which and distance to a well known landmark such as a navigational aid or a small island or in any terms which will assist a responding station in locating the vessel in distress Include any information on vessel movement such as course speed and destination 6 State the nature of distress ie sinking fire etc followed by the type of assis...

Page 6: ... of your choice not included Recommended screws 316 Stainless Self Tapping 8G 1 4 2 25 4mm Pan Round Head Note H1P is supplied with a H1 non powered cradle for secure mounting in a secondary position H1 Tethered Handset H1P Portable Handset H1 Non powered Cradle H1P Charging Cradle H1 Bulkhead Connector Recommended screws 316 S S Self Tapping 8G 1 4 2 25 4mm Pan Round Head ...

Page 7: ...r to the positive lead of the appropriate rating for the circuit ie 2A for each handset Cradle and Bulkhead Connector wiring color codes H1P Charging Cradle and H1 Bulkhead Connector Wiring Diagram Power ve FUSE Red Black Negative ve Red DC positive ve 12 24 volts Black DC negative ve Always use a fuse or circuit breaker installed near the battery end or bus bar end Do not connect directly to a ba...

Page 8: ...following power connection requirements when choosing a cradle position H1 The spiral tether connects via a removable plug to the Bulkhead Connector wired to power 12V or 24V DC The spiral tether stretches to a maximum length of approximately 2M 6ft H1P The H1P is held and recharged via a charging cradle that is wired to power 12V or 24V DC CAUTION Ensure that the minimum safe compass distance is ...

Page 9: ...d for the H1P cradle power cable 3 Mark the holes required and drill them 4 H1P cradle Feed the power cable into the power cable hole Use marine sealant to waterproof holes if mounting externally Note Side holes allow optional surface mounting 6 Snap the cover plate into place Power cable Mounting Power cable 5 Secure with fastenings of your choice Use marine sealant to waterproof holes if mountin...

Page 10: ...e of the H1 stretches to a maximum length of approximately 2M 6ft HINT The Bulkhead Connector base is supplied pre assembled and can be rotated in 90 degree increments prior to fastening to achieve a convenient installation angle once the H1 plug is inserted Arrows on the Mounting Base indicate the correct vertical orientation for most installations CAUTION Ensure that the minimum safe compass dis...

Page 11: ...ss the power cable of the Mounting Base through the power cable hole Optional Waterproof Cap not shown 3 If required eg exterior installations add the Waterproof Cap in steps 3a and 3b 1 Use the Mounting Base as a template for marking the position of mounting holes and the power cable hole 5 Add marine sealant to waterproof the holes if mounting externally Secure with fastenings of your choice Opt...

Page 12: ...Slide the handset upwards To connect power to a handset H1 1 Connect the H1 plug to the H1 Bulkhead Connector 2 Tighten the plug lock ring clockwise one quarter turn for a secure and watertight connection H1P 1 Place the H1P into the charging cradle Note Before first time use ensure the H1P is charged 1 Place 2 Snap ...

Page 13: ...set Connection FAQs pg15 Confirm a handset is receiving DC power via these visual checks H1 The power light above the touchscreen indicates a handset is On when the screen is Off H1P Select the Battery Charge icon in the Status Bar When an H1P is placed into a non powered cradle the power light will flash to indicate the H1P is not charging Note When turned On after Sleep Shutdown and Reboot a han...

Page 14: ...ified by the M1 serial number eg CORTEX 95211616 Note The Cortex V1 package M1 H1 ships with the handset pre configured to the M1 5 Key the WiFi Password found on the label supplied with the M1 6 Select CONNECT to save Text connected will confirm the connection 7 Select the Back key to close the WiFi status To connect a handset to an M1 Place supplied WiFi label here Caution The WiFi SSID or passw...

Page 15: ...ce between the handset and M1 on board Some objects and materials may provide interference to degrade the WiFi signal strength See To connect a handset to an M1 pg14 Follow Step 3 to identify and connect to the WiFi Note The WiFi status icon on the M1 will illuminate green when a handset or app makes a connection If the screen displays No GPS position while beeping alarm touch the screen or any ke...

Page 16: ...r or Vesper Marine To program your MMSI with a handset Main Menu Touch on the wrench icon to open the Configuration Menu Vessel Vessel Identification MMSI Enter MMSI number Name Enter the vessel s name Callsign Enter the vessel s callsign Vessel Type Select from the list MMSI Programming Warning For Customers in the USA This device must be programmed with data corresponding to the vessel on which ...

Page 17: ...Select tick icon to save the number The handset will display the following Once set you cannot change your ID Please verify that your id is xxxxxxxxxx If the number is correct select THAT IS MY ID Note The operation can be canceled by selecting the back key You can program your ATIS identification number only once Contact your Vesper Marine dealer if you must change your ATIS ID after entering it ...

Page 18: ...ric shock injury or damage to the handset or other property Protect the H1 spiral cable by avoiding bending twisting pulling heating or placing heavy items on it Do not attempt to repair or modify or re manufacture the handset It is equipped with an internal rechargeable battery to be replaced only by Vesper Marine or an authorized Vesper Marine dealer Do not open disassemble crush bend deform or ...

Page 19: ...ed specifications are subject to change without notice or obligation Dimensional measurements based on metric Dimensions and Specifications 164 8mm 6 1 2 71 8mm 2 13 16 21 4mm 7 8 75 6mm 3 73 3mm 2 7 8 18mm 11 16 25 1mm 1 Back Front 20 8mm 13 16 5 8 13 16 58 7mm 164 8mm 6 1 2 71 8mm 2 13 16 21 4mm 7 8 75 6mm 3 73 3mm 2 7 8 18mm 11 16 25 1mm 1 Back Front 20 8mm 13 16 58 7mm 164 8mm 6 1 2 71 8mm 2 1...

Page 20: ...ountry for more information For Customers in the USA This device must be programmed with data corresponding to the vessel on which it will be installed Programming must be carried out by a Vesper Marine dealer The included instructions contain information on how to verify the correct programming WARNING It is a violation of the rules of the Federal Communications Commission to input an MMSI that h...

Page 21: ... over one gram of tissue or 4 0 watts kg W kg averaged over ten grams of tissue The highest SAR value for your handset is 0 01 W kg 1 g when tested for use Front of Face 25mm and 0 07 W kg 10 g for Extremities 0mm Regulatory Information To view regulatory marks and related information Main Menu Touch on the wrench icon to open the Configuration Menu Systems Certifications Water Resistant Propertie...

Page 22: ...e chooses to replace the unit it may be replaced with a factory reconditioned unit or a new unit at its sole discretion Where a replacement is provided the original product becomes the property of Vesper Marine and the warranty will remain from the original purchase date THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STATUT...

Page 23: ...23 ...

Page 24: ...ons of this product may use software licensed under open source license agreements Source code for the applicable software is available upon request from Vesper Marine Ltd Member of 45 Sale Street Freemans Bay Auckland New Zealand Phone 64 9 950 4848 info vespermarine com www vespermarine com www facebook com vespermarine Vesper Marine declares that this product is in compliance with Directive 201...

Reviews: