Summary of Contents for Liebert MicroPOD

Page 1: ...Liebert MicroPOD 120V Installer User Guide...

Page 2: ...any installation or operational issues with your product check the pertinent section of this manual to see if the issue can be resolved by following outlined procedures Visit https www VertivCo com e...

Page 3: ...Installation 10 5 Startup Procedure 12 5 1 Electrical Connections 12 5 2 Pluggable Connections 12 5 3 Hardwire Connections 13 6 Indicator Lamps 16 6 1 Utility Indicator Lamp 16 6 2 UPS Indicator Lamp...

Page 4: ...vacuum cleaners or electric drills into the UPS output receptacles WARNING Do not modify the cables in any way Consult your local Emerson representative if the AC cords do not match the utility recep...

Page 5: ...ARNING When the Liebert MicroPOD is in Utility position maintenance bypass mode the power to the connected load is not filtered or conditioned by the UPS Vertiv Liebert MicroPOD Installer User Guide 5...

Page 6: ...onal information Utility lamp indicates local power is available and the load may be transferred to bypass the UPS UPS lamp indicates UPS power is available and the load may be transferred to the UPS...

Page 7: ...TILITY maintenance bypass In UPS mode the power is routed through the UPS system delivering conditioned power to the load as shown in Figure 2 1 below Figure 2 1 UPS mode of operation In Utility mode...

Page 8: ...Figure 2 3 Liebert MicroPOD connections Vertiv Liebert MicroPOD Installer User Guide 8...

Page 9: ...type of configuration 4 If you already have a UPS installed turn off all connected loads and unplug them from the UPS Turn off the UPS and disconnect the input cord 5 Attach the two Liebert MicroPOD s...

Page 10: ...ng on your application utilizing the rack mount brackets provided 4 Determine the desired position and direction for the Liebert MicroPOD face it in that direction then attach the brackets to the Lieb...

Page 11: ...OD mounting bracket location CAUTION Before installing open all branch rated circuit breakers at the nearest disconnect turn UPS off and disconnect all cords to and from the UPS Vertiv Liebert MicroPO...

Page 12: ...on Plug the Liebert MicroPOD input cord labeled UTILITY into the utility outlet wall receptacle WARNING The Liebert MicroPOD is now electrically live The Utility lamp amber should be illuminated 2 Plu...

Page 13: ...lectrical noise Conduit used alone without a grounding conductor wire is not an acceptable connection Size ground protective earth conductors equal in size to circuit conductors Wiring Instructions 1...

Page 14: ...V Table 2 1 Breaker specifications To make the hardwire connections 1 Remove the wiring access doors by removing the two Phillips head screws that secure them 2 Determine which of the two available co...

Page 15: ...anual 10 Verify that the UPS lamp green on the Liebert MicroPOD is illuminated If so transfer the rotary switch from UTILITY to UPS The load is now being supplied with conditioned power through the UP...

Page 16: ...h If utility power is not present this lamp will be off and the UPS will supply battery backup power to connected loads 6 2 UPS Indicator Lamp This green lamp is illuminated when output power is avail...

Page 17: ...cables connecting the UPS to the Liebert MicroPOD 5 You may now service the UPS 7 2 Transfer to UPS To transfer to UPS from maintenance bypass utility use the following steps 1 Reconnect the UPS to t...

Page 18: ...d 10 ft 3m cord L5 30P on attached 10 ft 3m cord Connection to UPS Input 5 15R 5 15 20R T type L5 30R L5 30R L5 30R Connection to UPS Output 5 15P on attached 6 ft 1 8m cord 5 20 P on attached 6 ft 1...

Page 19: ...dels MODEL POWER DISTRIBUTION BOX MODEL MP2 115HW MP2 120HW MP2 130HW USED WITH LIEBERT GXT RATING VA 500 1500 2000 3000 Dimensions W x D x H in mm Unit 15 51 x 3 03 x 3 46 394 x 77 x 88 Shipping 18 5...

Page 20: ...ert MicroPOD units pluggable and hardwire This Liebert MicroPOD is intended for use with a UPS meeting all the following requirements UPS input cord is compatible with the rating and type of receptacl...

Page 21: ...urn on UPS Refer to UPS user manual UPS input and or output cord not connected to Liebert MicroPOD Refer to Liebert MicroPOD installation instructions in this manual Installation on a Liebert GXT UPS...

Page 22: ...Vertiv Liebert MicroPOD Installer User Guide 22...

Page 23: ...ter with your Liebert product Please call or e mail us Technical support e liebert upstech vertivco com p 1 800 222 5877 menu option 1 Monitoring support e liebert monitoring vertivco com p 1 800 222...

Page 24: ...Vertiv Liebert MicroPOD Installer User Guide 24 This page intentionally left blank...

Page 25: ......

Page 26: ...logos referred to are trade names trademarks or registered trademarks of their respective owners While everyprecaution has been taken to ensure accuracyand completeness herein VertivCo assumes no resp...