background image

 

TP-BC12-300 

AC to DC12V UNINTERRUPTED POWER SUPPLY

   

User Manual 

Specifications and Features: 

 

210W Total Max.   

DC power output 12A Max. (@12V) 

Charge current 5A Max. (@14V). 

 

Net weight, only 4.63 lbs/2.1kg 

 

Dimensions 252*54*190 m/m (W*H*D) 

 

Over Voltage protection 

 

Over Current protection 

 

Quiet Internal Cooling Fan 

 

Input Voltage: Selectable AC input voltage 

-115 Vac at 50/60Hz ([email protected].) 

-230 Vac at 50/60Hz ([email protected].) 

 

Super Regulation: 

      Works with AC input from 90 to 265Vac 

 

Back-up Power Supply System   

 

Compatible with Solar and Wind Charge Controllers 

 

Summary of Contents for TP-BC12-300

Page 1: ... weight only 4 63 lbs 2 1kg Dimensions 252 54 190 m m W H D Over Voltage protection Over Current protection Quiet Internal Cooling Fan Input Voltage Selectable AC input voltage 115 Vac at 50 60Hz 5 1A F L 230 Vac at 50 60Hz 2 6A F L Super Regulation Works with AC input from 90 to 265Vac Back up Power Supply System Compatible with Solar and Wind Charge Controllers ...

Page 2: ...n is incorrect 3 4 CHD Floating Indicator Light GREEN when battery is in floating mode 3 5 CHG Charging Indicator Light YELLOW when battery is in charging mode 3 6 WET Battery Type Indicator Green LED light on when battery type selector is set on WET position 3 7 GEL Battery Type Indicator Yellow LED light on when battery type selector is set on GEL position 4 LOAD Output Terminal Block For connec...

Page 3: ...y of battery is correctly connected select WET for wet battery GEL for GEL or AGM battery You may connect a solar panel or wind turbine to the BATTERY terminal at the same time by connecting a solar panel or wind turbine controller to the battery terminals please make sure it is as the same polarity as battery otherwise it will damage the battery and the control circuit 1 2 3 4 A B C D 4 3 2 1 D C...

Page 4: ...ind turbine to the BATTERY terminal at the same time if AC failed when the battery voltage lower than 10 7V the LOAD output will turn off but if the output voltage of the solar panel or wind turbine is higher than the battery voltage the battery will be charged by the solar panel or wind turbine when the battery voltage is back to 12 6V the LOAD output will recover automatically The maximum load o...

Page 5: ...to turn on when the inner temperature of unit over 50C and will turned off when the temperature less than 45C NOTICE 1 DON T CONNECT THE PS TO 24V BATTERY The PS was designed for 12V system Connection to the wrong battery will damage the PS 2 THE AC SWITCH MUST BE TURNED OFF AT ANY TIME WHEN THE BATTERY IS CHANGED 3 Select the correct battery type on the panel wrong selection will damage the batte...

Page 6: ... device to the PS should be 14AWG min Please keeping the connect points clean to avoid spark or electrical leakage 6 When connecting a solar panel or wind turbine controller to the PS please make sure of the correct polarity 7 Product label ...

Page 7: ...ng a spark Battery Low Voltage protection When the AC is OFF or has failed if the battery voltage is lower than 10 7V 0 2V the model will turn off the battery and the output on LOAD When AC returns or the battery voltage returns to 12 6V 0 2V then the output on LOAD will recover automatically Load Over Current Protection the model will automatically shut down if the load is over 12A when the load ...