REV : 5
REV DATE : 6/19
DPN001430
Page :1 /1
WATER/GLYCOL DIGITAL SCROLL COMPRESSOR MODELS
Fo
rm
N
o.
: D
P
N
00
10
40
_R
E
V
4
PIPING SCHEMATIC
LIEBERT DS
NOTE: SCHEMATIC REPRESENTATION SHOWN. THIS SCHEMATIC DOES NOT IMPLY OR DEFINE ELEVATIONS
AND COMPONENT LOCATION, UNLESS SPECIFICALLY NOTED.
Service
Valve
Service
Valve
Components are not supplied by Liebert but are
required for proper operation and maintenance
Field installed at highest point in system on return
line to pumps
Locate at tops of all risers and any intermediate
system high points
External
Equalizer
Sensing Bulb
NOTE: TWO REFRIGERATION CIRCUITS PROVIDED.
SINGLE REFRIGERATION CIRCUIT SHOWN FOR CLARITY.
FIELD PIPING
FACTORY PIPING
Check
Valve
EVAPORATOR
COIL
Expansion
Valve
COMPRESSOR
LIQUID
SUCTION
Sight
Glass
Solenoid
Valve
Filter Drier
PARADENSER®
CONDENSER
TO SECOND
REFRIGERATION
CIRCUIT
Hose
Bib
Shut-Off Valve
Hose
Bib
Shut-Off Valve
Flow-Regulating
Valve
Flow Switch Supplied
with Dual Pump
Systems
Pressure Port
Gate Valves
Check Valves
(on Dual Pump
Systems only)
GLYCOL
PUMPS
EXPANSION
TANK
Hose
Bib
SERVICE / SCHRADER (ACCESS) CONNECTION WITH VALVE CORE
SERVICE / SCHRADER (ACCESS) CONNECTION NO VALVE CORE
OPTIONAL FACTORY PIPING
Aquastat
Sensing
Bulbs
Pressure
Port
2-Way
Motorized
Ball Valve
Optional 3-Way
Motorized Ball
Valve
Optional Dual Pump System shown
DRYCOOLER
(Glycol)
Air Vents
(typical)
Shut-Off Valve
Shut-Off Valve
RETURN
SUPPLY
RETURN
SUPPLY
DISCHARGE
COOLING TOWER
AND PUMP SYSTEM
BY OTHERS
CUSTOMER
HEAT REJECTION
LIEBERT
HEAT REJECTION
LIEBERT DS UNIT
(and associated piping)
RETURN
SUPPLY
Relief valve(s) supplied
with 50 Hz EU CE units rated
maximum 480 PSIG (33 Bar).
Pressure
Transducer
To
iCOM
Control
From
iCOM
Control
53-70kW Digital
Solenoid Valve
28-42kW Digital Solenoid Valve
3
2
1
1
1
1
1
1
1
1
1
1
1
1
1
2
3
Threaded
Pipe Union
Typ. (4) Plcs.
1
Summary of Contents for Liebert Drycooler
Page 1: ...Liebert Air cooled Direct drive Drycooler Installer User Guide 50 Hz and 60 Hz ...
Page 10: ...Vertiv Liebert Drycooler Installer User Guide 6 This page intentionally left blank ...
Page 20: ...Vertiv Liebert Drycooler Installer User Guide 16 This page intentionally left blank ...
Page 24: ...Figure 4 2 Removing Protective Material Vertiv Liebert Drycooler Installer User Guide 20 ...
Page 34: ...Vertiv Liebert Drycooler Installer User Guide 30 This page intentionally left blank ...
Page 54: ...Vertiv Liebert Drycooler Installer User Guide 50 This page intentionally left blank ...
Page 62: ...Vertiv Liebert Drycooler Installer User Guide 58 This page intentionally left blank ...
Page 66: ...Vertiv Liebert Drycooler Installer User Guide 62 This page intentionally left blank ...
Page 68: ...Vertiv Liebert Drycooler Installer User Guide 64 This page intentionally left blank ...
Page 101: ...Vertiv Liebert Drycooler Installer User Guide ...