System Timers I - III (PGM 180, 181,182)
2-81
Chapter 2: SBX IP Offline PCAdminPro
SBX IP - PC Admin Guide
Station Auto Release
Timer
020-300
(3 digits)
060
(sec)
If a station hears ring back tone and no action is taken,
this timer is initiated. When this timer expires the station
is released.
Unsupervised Conference
Timer
00-99
(2 digits)
10
(min)
Establishes the amount of the time an unsupervised
conference can continue after the initiator of the
conference has exited the conference
Wake-up Fail Ring Timer
00-99
(2 digits)
20
(sec)
After a Wake-up fail ring invokes on the System
Attendant, the alarm ring continues during the length of
this timer. If this timer expires, the Alarm ring will
terminate.
Warm Line Timer
01-20
(2 digits)
05
(sec)
User takes no action after lifting handset or pressing the
[SPEAKER] button and the warm line timer expires, then
the idle line selection for warm line is activated.
Wink Timer
010-200
(3 digits)
010
(10ms)
The Time Duration of Seize Acknowledge Signal to DID
line.
Enblock Int Digit Timer
01-20
(2 digits)
15
(sec)
After timer expires, Setup is sent.
CCR Time Out Timer
000-300
(3 digits)
010
(sec)
When this timer expires, CCR is activated
DID Inter Digit Timer
01-20
(2 digits)
05
(sec)
This timer is used for the DID type 2 feature. In DID type
2, the SBX IP system will wait for new DID digits to be
received until this timer expires or the call routing of DID
type 2 is executed.
FAX Tone Detect Timer
01-10
(2 digits)
05
(sec)
Establishes the time allowed for a FAX tone to be
detected before disconnection.
FAX CO Call Timer
1-5
(1 digit)
1
(min)
Establishes the time allowed for a FAX call before
disconnection.
System Timers - III (PGM 182)
ITEM
RANGE
DEFAULT
REMARK
Release 3.5