O
VERVIEW
DX-120 Installation and Maintenance Manual
- 38 -
Specifications
(continued)
R
EGULATORY
D
ATA
S
IGNALING
(
INTERNAL
) D
ATA
Specifications (continued on next page)
FCC Registration Numbers
For systems configured for key system operation (each
CO line appears on its own dedicated button).
D6XTAI-40144-KF-T
For systems configured for hybrid operation (CO lines
may be accessed by dial codes and Pool/Loop buttons).
D6XTAI-40145-MF-T
Audible Signals
Signal
Frequency
Cadence
CO Line Ringing:
Scheme 0
Scheme 1
Scheme 2
Scheme 3
Scheme 4
Scheme 5
Scheme 6
Scheme 7
Distinctive 1
Distinctive 2
Distinctive 3
Distinctive 4
SLT
N/A
N/A
N/A
-SLT bell-
300ms On, 400ms Off, 300ms On, 4 seconds
Off
1 second On, 3 seconds Off
1 second On, 3 seconds Off
follows ring cadence of Ring Scheme selected
follows ring cadence of Ring Scheme selected
follows ring cadence of Ring Scheme selected
follows ring cadence of Ring Scheme selected
follows ring cadence of Ring Scheme selected
Intercom Ringing:
Scheme 0
Scheme 1
Scheme 2
Scheme 3
Scheme 4
Scheme 5
Scheme 6
Scheme 7
Distinctive 1
Distinctive 2
Distinctive 3
Distinctive 4
SLT
N/A
N/A
N/A
-SLT bell-
1 second On, 3 seconds Off
1 second On, 3 seconds Off
300ms On, 400ms Off, 300ms On, 4 seconds
Off
follows ring cadence of Ring Scheme selected
follows ring cadence of Ring Scheme selected
follows ring cadence of Ring Scheme selected
follows ring cadence of Ring Scheme selected
follows ring cadence of Ring Scheme selected
Message Wait Callback
follows ring cadence of Ring Scheme selected
Summary of Contents for comdial DX-120